Main Title Impregnation of concrete pipe for corrosion resistance and strength improvement /
Author Ludwig, Allen C.
CORP Author Southwest Research Inst., San Antonio, TX.;Municipal Environmental Research Lab., Cincinnati, OH.
Publisher Municipal Environmental Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency ; Available through the National Technical Information Service,
Year Published 1980
Report Number EPA-600/2-80-009; EPA-S-802651; SwRI-11-5016
Stock Number PB80-190234
OCLC Number 06541389
Subjects Sewer-pipe. ; Pipe, Concrete--Corrosion. ; Sulfur in building. ; Sulphur in building
Additional Subjects Sewer pipes ; Concrete pipes ; Field tests ; Corrosion resistance ; Strength ; Impregnating ; Sulfur ; Hydrofluoric acid
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30000A92.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAM  TD172.E46 600 1980, no.009 Region 1 Library/Boston,MA 04/29/2016
EJAD  EPA 600/2-80-009 Region 3 Library/Philadelphia, PA 03/14/1997
EJBD ARCHIVE EPA 600-2-80-009 Headquarters Library/Washington,DC 01/22/2014
EJBD  EPA 600-2-80-009 Headquarters Library/Washington,DC 03/29/2016
EKAM  TD172.E46 600 1980, no.009 Region 4 Library/Atlanta,GA 11/20/1998
ELBD  EPA 600-2-80-009 AWBERC Library/Cincinnati,OH 01/02/1998
ESAD  EPA 600-2-80-009 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB80-190234 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation x, 50 pages : illustrations ; 28 cm.
Abstract The program was undertaken to field test concrete sewer pipe that had been impregnated with sulfur or hydrofluoric acid. This program was a follow-on to a previous laboratory study sponsored by EPA entitled, Impregnation of Concrete Pipe, 11024EQE 06/71. In a subsequent grant extension to the program, strength improvements using the sulfur formulations were investigated with a view to reducing costs by elimination of the steel reinforcing in certain sizes of concrete pipe. In 1975, nearly 1400 feet (427 m) of impregnated sewer lines were installed in four Texas cities, including Dallas, Beaumont, Pecos, and Harlingen. These lines have been monitored since that time and the results of this monitoring, as well as a discussion of the strength improvement due to sulfur impregnation, are reported.
Notes Grant no. S802651.
Place Published Cincinnati Springfield, Va.
Corporate Au Added Ent Southwest Research Institute.; Municipal Environmental Research Laboratory.
Title Ser Add Ent Research reporting series. Environmental protection technology ; EPA-600/2-80-009.
PUB Date Free Form 1980
Series Title Untraced Environmental protection technology series ; EPA-600/2-80-009
NTIS Prices PC A04/MF A01
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
Merged OCLC records 6542081
OCLC Time Stamp 20160419143449
Language eng
SUDOCS Number EP 1.23/2:600/2-80-009
Origin OCLC
Type MERGE
OCLC Rec Leader 01611cam 2200385Ii 45020