Main Title |
Conceptualized Fly-Ash and Sulfur Dioxide Scrubbing System with By-Product Recovery. |
Author |
Carlso, Gary E. ;
Jame, David E. ;
|
CORP Author |
Babcock and Wilcox Co., Barberton, Ohio. Power Generation Div. |
Year Published |
1971 |
Report Number |
CPA-22-69-162; 0967; |
Stock Number |
PB-210 354 |
Additional Subjects |
( Air pollution ;
Flue gases) ;
( Air pollution control equipment ;
Flue gases) ;
( Sulfur dioxide ;
Air pollution control equipment) ;
( Particles ;
Air pollution control equipment) ;
Theory ;
Concepts ;
Fly ash ;
Scrubbers ;
Absorbers(Equipment) ;
Design ;
Adsorbents ;
Magnesium oxides ;
Sulfites ;
Cost estimates ;
Capital costs ;
Operating costs ;
Magnesium sulfites ;
Magnesium oxide scrubbing ;
Waste gas recovery ;
Air pollution control
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB-210 354 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
18p |
Abstract |
Based on the experimental data gathered, a conceptualized air pollution control system was established. The system was designed to remove 99% of the fly-ash and 97 1/2% of the sulfur dioxide contained in an assumed but typical flue gas. A venturi-type scrubber was chosen to remove the fly-ash, and tray-type absorber was chosen for sulfur dioxide absorption. A slurry of magnesium oxide and magnesium sulfite is the active absorbent. Drawings show the side and plan views of scrubbing venturis and sulfur dioxide absorbers as integrated into an 800 MW boiler system. The outline and location of the major pieces of equipment are also shown. The cost of the conceptualized system was then developed. Whenever possible, commercially available equipment was utilized in the design and cost estimate. When commercial equipment was not available, suitable conceptual equipment designs were developed, and the cost of the equipment established. |
Highlights Notes |
Presents the design and costs of a system which uses wet scrubbing for fly ash removal and magnesium sulfite and oxide for SO2 removal. |
PUB Date Free Form |