Main Title |
Evaluation of utility boiler radiant furnace resident time/temperature characteristics : field tests and heat transfer modeling / |
Other Authors |
Author |
Title of a Work |
Cetegen, B. |
W. Richerter, |
Reese, J. L., |
LaFond, J., |
Folsom, B. A., |
Payne, R. |
Lachapelle, David G., |
|
Publisher |
U.S. Environmental Protection Agency, Air and Energy Engineering Research Laboratory, Center for Environmental Information |
Year Published |
1987 |
Report Number |
EPA/600-S7-87-018 |
OCLC Number |
896735180 |
Subjects |
Boilers--Environmental aspects ;
Combustion gases--Environmental aspects ;
Air quality management--United States
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-S7-87-018 |
In Binder |
Headquarters Library/Washington,DC |
10/18/2018 |
ELBD ARCHIVE |
EPA 600-S7-87-018 |
In Binder Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
|
Collation |
11 pages : illustrations ; 28 cm |
Notes |
Caption title. At head of title: Project summary. "Sept. 1987." "EPA/600-S7-87-018." |
Contents Notes |
This report describes an investigation of the adequacy of a modeling approach in predicting the thermal environment and flow field of pulverized-coal-fired utility boilers. Two 420 MW[subscript 3] coal-fired boilers were evaluated: a single-wall-fired unit and a tangentially fired unit, representing the two commonest boilers in the U.S. Extensive field measurements were conducted on each unit to determine detailed temperature, heat flux, gas species composition, and flow field data for a range of operating conditions. Separate modeling approaches were used to predict boiler thermal performance and flow characteristics. A three-dimensional zone method of analysis was used to predict local and overall heat transfer, temperature profiles, and fuel burnout. Such predictive tools provide a sophisticated treatment of radiative heat transfer, but are decoupled from the furnace flow field. This input to the heat transfer code was obtained from detailed measurements in reduced scale isothermal physical flow models of the two boilers. Comparisons between model predictions and the detailed field measurement data have demonstrated the viability of this approach in predicting furnace performance, and in extrapolating limited available data to alternate operating conditions. Overall thermal performance can, in general, be accurately predicted; however, the analysis has shown that the correct quantitative prediction of local temperatures and other properties requires anaccuratee specification of inhomogeneities in boilerinputu conditions, in the boiler flow field, and in the local distribution of wall ash deposits. |
Place Published |
Research Triangle Park, NC Cincinnati OH |
Corporate Au Added Ent |
Air and Energy Engineering Research Laboratory. |
PUB Date Free Form |
1987 |
BIB Level |
m |
Medium |
unmediated |
Content |
text |
Carrier |
volume |
Cataloging Source |
RDA |
OCLC Time Stamp |
20141121154342 |
Language |
eng |
Origin |
OCLC |
Type |
CAT |
OCLC Rec Leader |
03349nam 2200433Ii 45020 |