Main Title |
FTIR emission test at an iron foundry : GM Powertrain Group, General Motors Corporation, Saginaw Metal Casting Operations, Saginaw, Michigan |
Other Authors |
|
CORP Author |
Midwest Research Inst., Kansas City, MO.;Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards. |
Publisher |
U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards, Emissions Monitoring and Analysis Division, Emission Measurement Center, |
Year Published |
1999 |
Report Number |
EPA-454/R-99-031; EPA-68-D-98-027; PB2001105695 |
Stock Number |
PB2001-105695 |
OCLC Number |
46801198 |
Additional Subjects |
Iron and steel industry ;
Foundaries ;
Air pollution sampling ;
Metal casting ;
Foundry practice ;
Exhaust emissions ;
Air pollution control equipment ;
Data collection ;
Wet scrubbers ;
Test procedures ;
National Emission Standards for Hazardous Air Pollutants(NESHAP) ;
Saginaw(Michigan) ;
Maximun Achievable Control Technology(MACT)
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EKBD |
EPA-454/R-99-031 |
|
Research Triangle Park Library/RTP, NC |
05/04/2001 |
NTIS |
PB2001-105695 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
1 v. (various pagings) : ill., facsims, plans ; 28 cm. |
Abstract |
The US EPA is investigating iron and steel foundries to identify and quantify HAPS emitted from cupolas; electric arc furnaces; and pouring, cooling and shakedown operations of sand mold casting processes. GM Corporation, Saginaw Casting Operation (GMC) Saginaw, MI was selected by EPA as the host facility at which to (1) characterize HAP emissions from cupolas that are controlled by wet scrubbers, and (2) assess wet scrubber performance in controlling HAP emissions from cupolas. GMC was selected because EPA deemed this facility to be representative of a large segment of the sand casting foundry industry and a GMC operates a relatively large cupola that is controlled by a wet scrubber. Fourier Transform Infrared emission test runs were conducted at the cupola inlet and outlet locations. Additionally, MRI collected tedlar bag samples from pouring, cooling, shake-out ducts and analyzed by FTIR. |
Notes |
EPA project officer: Michael Ciolek. EPA project officer: Michael Toney. "Author(s): EMAD"--Colophon. "September 1999." "EPA-454/R-99-031"--Cover. "MRI Project No. 104951-1-013-04." Includes bibliographical references (7-1). |
Place Published |
Research Triangle Park, N.C. : |
Supplementary Notes |
Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Corporate Au Added Ent |
United States. Environmental Protection Agency. Emissions Monitoring and Analysis Division. ; Emissions Measurement Center (U.S.) ; Midwest Research Institute (Kansas City, Mo.) |
Alternate Title |
Fourier transform infrared emission test at an iron foundry GM Powertrain Group, General Motors Corporation, Saginaw Metal Casting Operations, Saginaw, Michigan |
PUB Date Free Form |
{1999} |
NTIS Prices |
PC A16/MF A03 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20010424082301 |
Language |
eng |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01680nam 2200349Ka 45020 |