Main Title |
Test Design for Environmental Technology Verification (ETV) of Add-on NOx Control Utilizing Ozone Injection. |
Author |
VanOsdell, D. ;
Farmer, J. R. ;
Trenholm, A. ;
Clapsaddle, C. ;
Brna, T. G. ;
|
CORP Author |
Research Triangle Inst., Research Triangle Park, NC. ;Midwest Research Inst., Cary, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Publisher |
2000 |
Year Published |
2000 |
Report Number |
EPA-R826152-01-2; EPA/600/A-00/007; |
Stock Number |
PB2000-105761 |
Additional Subjects |
Nitrogen oxides ;
Air pollution control equipment ;
Ozone ;
Combustion kinetics ;
Boilers ;
Natural gas ;
Oxidation ;
Low temperature ;
Waste gas recovery ;
Performance evaluation ;
Technology assessment ;
Environmental Technology Verification Program ;
Air Pollution Control Technology Program
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2000-105761 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
16p |
Abstract |
The paper discusses the test design for environmental technology verification (ETV) of add-on nitrogen oxides (NOx) control utilizing ozone injection. Operated by the Research Triangle Institute, the Air Pollution Control Technology (APCT) program is one of 12 ETV pilot programs. Add-on NOx air pollution control technologies are among those being verified, and the Low-Temperature Oxidation (LTO) technology is the first NOx control technology planned for verification by the APCT program. LTO uses ozone injection into the gas phase of a combustion or chemical process waste gas stream to oxidize NOx molecules to higher order NOx, which can be removed by wet or semi-dry scrubbing. Ozone is produced on-site and on-demand from stored oxygen. As a low-temperature process, it can be installed as an end-of-pipe system. |
Supplementary Notes |
Presented at Forum 2000, Rosslyn, VA., March 23-24, 2000. See also PB97-160006. Prepared in cooperation with Midwest Research Inst., Cary, NC. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Category Codes |
68A; 81A; 99B |
NTIS Prices |
PC A03/MF A01 |
Primary Description |
600/13 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
020201260 |
Origin |
NTIS |
Type |
CAT |