Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 3 OF 3

OLS Field Name OLS Field Data
Main Title Recommended practice for the use of Parshall flumes and Palmer-Bowlus flumes in wastewater treatment plants /
Author Kulin, Gershon.
Other Authors
Author Title of a Work
Schuk, Walter W.
CORP Author National Bureau of Standards (NEL), Gaithersburg, MD. Fluid Engineering Div.;Municipal Environmental Research Lab., Cincinnati, OH.
Publisher Municipal Environmental Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency,
Year Published 1984
Report Number EPA-600/2-84-186; 78-D-X0024-1
Stock Number PB85-122745
OCLC Number 17968231
Subjects Sewage--Purification. ; Parshall flumes. ; Flumes.
Additional Subjects Flumes ; Sewage treatment ; Flow rate ; Open channel flow ; Flow measurement ; Depth ; Operations ; Specifications ; Installing ; Parshall flumes ; Calibrating ; Accuracy ; Maintenance ; Performance evaluation ; Comparison ; Tables(Data) ; Sewage treatment plants ; Palmer-Bowlus flumes
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=5000141O.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD ARCHIVE EPA 600-2-84-186 Headquarters Library/Washington,DC 03/05/2012
NTIS  PB85-122745 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 07/22/2019
Collation vi, 57 p. : ill. ; 28 cm.
Abstract Parshall and Palmer-Bowlus flumes are suitable for in-plant open channel flow measurement of raw wastewater and treated effluent as well as wastewater in intermediate stages of treatment. Parshall flumes are empirical devices which must be fabricated and installed according to specific requirements in order to yield the 'standard' values of discharge. The discharge of Palmer-Bowlus flumes can be determined analytically within specified error limits provided that described criteria for construction and installation are met. The accuracy of a flume-based measuring system depends upon a combination of the accuracies of the flume itself and the secondary instrumentation. The basic uncertainty of properly constructed and installed flumes is about + or - 3 percent. Suggested methods of calibrating and monitoring the performance of the flumes and secondary instruments are described.
Notes "EPA-600/2-84-186." "November 1984." "EPA 78-D-X0024-1." "PB85-12275." "Project officer, Walter W. Schuk."
Place Published Cincinnati, Ohio
Corporate Au Added Ent United States. Environmental Protection Agency. Office of Research and Development.; Municipal Environmental Research Laboratory.
PUB Date Free Form 1984
BIB Level m
Cataloging Source OCLC/T
OCLC Time Stamp 20120229163433
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01375cam 2200361Ka 45020