Main Title |
Evaluation of Landfill-Liner Designs. |
Author |
Peyton, R. L. ;
Schroeder, P. R. ;
|
CORP Author |
Missouri Univ.-Columbia. Dept. of Civil Engineering. ;Army Engineer Waterways Experiment Station, Vicksburg, MS.;Environmental Protection Agency, Cincinnati, OH. Risk Reduction Engineering Lab. |
Publisher |
c1990 |
Year Published |
1990 |
Report Number |
EPA/600/J-90/485; |
Stock Number |
PB91-191460 |
Additional Subjects |
Linings ;
Earth fills ;
Land pollution control ;
Hazardous materials ;
Waste disposal ;
Design criteria ;
Performance evaluation ;
Hydraulic conductivity ;
Leakage ;
Mathematical models ;
Soil compacting ;
Subsurface drainage ;
Membranes ;
Slope ;
Reprints ;
Geosynthetic materials ;
Hydrologic Evaluation of Landfill Performance Model
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB91-191460 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
11p |
Abstract |
The effectiveness of landfill-liner designs is evaluated in terms of the slope, drainage length, and saturated hydraulic conductivity of the lateral drainage layer, the saturated hydraulic conductivity of the soil liner, and the fraction of the area under a synthetic liner where leakage is occurring. The evaluation is performed using Version 1 of the Hydrologic Evaluation of Landfill Performance (HELP) model. The effectiveness is quantified by comparing the lateral drainage rate to the vertical percolation rate expressed as percentages of the total inflow. The two multiple-liner systems specified in the Hazardous and Solid Waste Amendments (HSWA) minimum technology guidance are shown to have different leakage-detection characteristics. One system detects significant leakage before leakage percolates out of the landfill, whereas the other system detects leakage only after significant leakage percolates out of the landfill. Four other designs were also examined-two with single liners and two with double liners. The two HSWA designs detected leakage at lower synthetic-liner-leakage fractions, but all designs with composite liners were nearly equally effective in reducing leakage from landfills. (Copyright (c) 1990, ASCE.) |
Supplementary Notes |
Pub. in Jnl. of Environmental Engineering, v116 n3 p421-437 May/Jun 90. Prepared in cooperation with Army Engineer Waterways Experiment Station, Vicksburg, MS. Sponsored by Environmental Protection Agency, Cincinnati, OH. Risk Reduction Engineering Lab. |
NTIS Title Notes |
Journal article. |
Title Annotations |
Reprint: Evaluation of Landfill-Liner Designs. |
Category Codes |
68C; 48E |
NTIS Prices |
PC A03/MF A01 |
Primary Description |
600/14 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
119326201 |
Origin |
NTIS |
Type |
CAT |