Main Title |
Stack gas reheat evaluation / |
Author |
Menzies, W. R. ;
Muela, C. A. ;
Behrens, G. P.
|
Other Authors |
|
CORP Author |
Radian Corp., Austin, TX.;Industrial Environmental Research Lab., Research Triangle Park, NC. |
Publisher |
U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor], |
Year Published |
1980 |
Report Number |
EPA 600-7-80-051; EPA-68-02-2642 |
Stock Number |
PB80-196850 |
OCLC Number |
08862925 |
Subjects |
Flue gases--Desulfurization ;
Combustion ;
Flue gases--Desulphurization
|
Additional Subjects |
Air pollution control ;
Flue gases ;
Electric power plants ;
Economic analysis ;
Industrial wastes ;
Combustion products ;
Plumes ;
Concentration(Composition) ;
Sulfur dioxide ;
Reheating ;
Design ;
Performance evaluation ;
Coal fired power plants ;
Stack gas reheat ;
Flue gas desulfurization ;
Wet methods
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-7-80-051 |
|
Headquarters Library/Washington,DC |
09/28/2018 |
EKBD |
EPA-600/7-80-051 |
|
Research Triangle Park Library/RTP, NC |
01/16/2004 |
ELBD ARCHIVE |
EPA 600-7-80-051 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
NTIS |
PB80-196850 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
xi, 302 pages : illustrations, forms ; 28 cm. |
Abstract |
The report gives results of technical and economic evaluations of stack gas reheat (SGR) following wet flue gas desulfurization (FGD) for coal-fired power plants. The evaluations were based on information from literature and a survey of FGD users, vendors, and architect/engineer (A/E) firms. The report summarizes SGR processes and their features and their commercial operating experience. It addresses benefits and energy requirements associated with SGR, and describes a developed method for estimating reheat costs. SGR can protect equipment downstream of a wet scrubber from corrosion, reduce the potential for acid rainout near the plant stack, preclude visible stack plumes, and reduce ground-level pollutant concentrations by increasing plume buoyancy. |
Notes |
"Radian Corporation." "EPA 600-7-80-051." "March 1980." Cover title. Includes bibliographical references. "Contract no. 68-02-2642, program element no. INE827." |
Place Published |
Research Triangle Park, NC Springfield, Va. |
Access Notes |
Also available via the World Wide Web. |
Corporate Au Added Ent |
Industrial Environmental Research Laboratory (Research Triangle Park, N.C.); Radian Corporation. |
Title Ser Add Ent |
Research reporting series. Interagency energy-environment research and development ; EPA-600/7-80-051. |
NTIS Title Notes |
Final rept. Jun 77-Feb 80. |
PUB Date Free Form |
1980 |
Series Title Untraced |
Interagency energy/environment R & D program report ; EPA-600/7-80-051 |
Category Codes |
13B; 68A; 97R |
NTIS Prices |
PC A14/MF A01 |
Primary Description |
600/13 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
Control Number |
323781234 |
OCLC Time Stamp |
20130628112038 |
Language |
eng |
SUDOCS Number |
EP 1.23/8:600/7-80-051 |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01573cam 2200361Ia 45020 |