Main Title |
Nitric Oxide Reduction in Kilns and Heaters by Fuel/Air Staging. |
Author |
Hunter, S. C. ;
Yang, R. J. ;
Hall, R. E. ;
|
CORP Author |
KVB, Inc., Irvine, CA.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Year Published |
1986 |
Report Number |
EPA-68-02-3690; EPA/600/D-86/151; |
Stock Number |
PB86-223088 |
Additional Subjects |
Air pollution control ;
Nitrogen oxide(NO) ;
Kilns ;
Heating equipment ;
Combustion products ;
Experimental design ;
Fuel air staging ;
Stationary sources
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB86-223088 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
18p |
Abstract |
The paper gives results of studies of the applicability and effectiveness of fuel/air staging (variously called In-furnace NOx Reduction, reburning, or biased firing) in controlling nitrogen oxide (NOx) emissions from refinery process heaters and cement kilns. The studies were conducted in three laboratory subscale furnaces and during a short-term test on a full-scale cement kiln. Test results showed that 80-85% reductions in stack NOx emissions can be achieved by biased firing and the optimum fuel split is around 50%. It was also found that reductions in NOx were slightly more effective with a retrofit lance approach. |
Supplementary Notes |
Presented at Air Pollution Control Association annual meeting (79th), Minneapolis, MN, Jun 86. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
PUB Date Free Form |
Jul 86 |
Category Codes |
13B; 68A |
NTIS Prices |
PC A02/MF A01 |
Primary Description |
600/13 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
626815533 |
Origin |
NTIS |
Type |
CAT |