Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 316 OF 814

Main Title Evaluation of a Field Test Kit for Monitoring Lead in Drinking Water.
Author Schock, M. R. ; George, G. K. ;
CORP Author Environmental Protection Agency, Cincinnati, OH. Drinking Water Research Div. ;Technology Applications, Inc., Cincinnati, OH.
Publisher 1993
Year Published 1993
Report Number EPA/600/J-93/433;
Stock Number PB94-101896
Additional Subjects Lead(Metal) ; Water pollution detection ; Drinking water ; Water chemistry ; Testing ; Chemical analysis ; Sampling ; pH ; Spectrophotometers ; Standards ; Comparison ; Performance evaluation ; Reprints ; Test kits
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB94-101896 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 14p
Abstract The paper discusses important aspects of the conceptual design of evaluation of studies of the performance of proprietary analytical test kits for drinking water surveys and corrosion control studies. The Hach Lead-Trak test kit was tested for precision, accuracy, operator bias, and performance relative to a standard GFAAS methodology. A detection limit of 4 milligrams/L was observed, with generally accurate results for standards up to 100 milligrams/L. Best performance was found below 80 milligrams/L. Spike recoveries for 15 milligrams/L in six different drinking waters were good. Interferences from 13 important cations and eight important anions were tested for realistic concentrations. Calcium and sulfate caused positive bias; Zn, Fe, orthophosphate, tripolyphosphate and pyrophosphate caused significant negative bias. No operator bias was found. The test kit was extremely sensitive to the test pH, and failed on acidified samples.
Supplementary Notes Pub. in Jnl. of the American Water Works Association, v85 n8 p90-100 Aug 93. Prepared in cooperation with Technology Applications, Inc., Cincinnati, OH.
NTIS Title Notes Journal article.
Title Annotations Reprint: Evaluation of a Field Test Kit for Monitoring Lead in Drinking Water.
Category Codes 68D; 99A
NTIS Prices PC A03/MF A01
Primary Description 600/14
Document Type NT
Cataloging Source NTIS/MT
Control Number 332328734
Origin NTIS
Type CAT