Main Title |
Comparison of manual (grab) and vacuum type automatic sampling techniques on an individual and composite sample basis. |
CORP Author |
National Field Investigations Center-Denver, Colo. |
Publisher |
U.S. Environmental Protection Agency, Office of Enforcement, |
Year Published |
1974 |
Report Number |
EPA-330/1-74-001 |
Stock Number |
PB-257 633 |
OCLC Number |
09120488 |
Subjects |
Water--Pollution--Sampling ;
Sewage
|
Additional Subjects |
Samplers ;
Sewage ;
Monitoring ;
Field testing ;
Water analysis ;
Design criteria ;
Performance evaluation ;
Waste water ;
Statistical analysis ;
Water pollution sampling ;
Serco automatic samplers
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 330-1-74-001 |
|
Headquarters Library/Washington,DC |
11/27/2015 |
ELBD ARCHIVE |
EPA 330-1-74-001 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ELBD |
EPA 330-1-74-001 |
|
AWBERC Library/Cincinnati,OH |
02/27/2018 |
ERAD |
EPA 330/1-74-001 |
|
Region 9 Library/San Francisco,CA |
12/10/2012 |
NTIS |
PB-257 633 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
1 volume (various pagings) : illustrations, graphs ; 28 cm |
Abstract |
The National Field Investigations Center-Denver (NFIC-D) has been engaged in water quality and waste source evaluation studies since its inception. Due to the magnitude of the surveys, NFIC-D often has relied upon automatic samplers, particularly the SERCO, to collect samples of the wastewater streams. These samplers are used to collect water samples over specified periods for subsequent compositing; individual grab samples are collected manually. With the advent of compliance monitoring, the use of automatic samplers is expected to increase. Data provided by the manufacturer show that the automatic and manual sampling methods are equivalent. To confirm that the sampling methods are equivalent, NFIC-D conducted studies at a local wastewater treatment plant (WWTP) and statistically evaluated the results. This paper presents the results of these studies. |
Notes |
Appendices included. EPA-330/1-74-001 "September 1974." |
Contents Notes |
Introduction -- Summary and conclusions -- SERCO automatic sampler -- Field study procedure -- Statistical approach -- Statistical analysis of data -- Additional data evaluation -- Discussion. |
Place Published |
Denver, CO |
Corporate Au Added Ent |
United States. Environmental Protection Agency. Office of Enforcement.; National Field Investigations Center-Denver. |
PUB Date Free Form |
1974 |
NTIS Prices |
PC A03/MF A01 |
BIB Level |
m |
Medium |
unmediated |
Content |
text |
Carrier |
volume |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20180216055530 |
Language |
eng |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01639cam 2200397Ii 45010 |