Main Title |
Environmental Technology Verification (ETV) Testing of a Multi-Parameter Water Quality Sensor: Sensicore, Inc. WaterPOINT 870. |
Author |
James, R. ;
Mangaraj, R. ;
Willenberg, Z. ;
Dindal, A. ;
|
CORP Author |
Battelle Columbus Div., OH. ;Ohio Department of Public Utilities Division of Power and Water, Columbus.;Environmental Protection Agency, Research Triangle Park, NC. National Exposure Research Lab. |
Publisher |
Sep 2007 |
Year Published |
2007 |
Report Number |
EPA/600/R-07/135; NERL-RTP-HEASD-07-090; |
Stock Number |
PB2008-106039 |
Additional Subjects |
Environmental Technology Verification Testing ;
Water quality sencor ;
Sensicore Inc waterPOINT 870 ;
Environmental Technologies ;
Performance verification ;
Information dissemination ;
Environmental Technology Verification (ETV) Program ;
Quality Assurance (QA) protocols
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2008-106039 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
34p |
Abstract |
The U.S. Environmental Protection Agency (EPA) supports the Environmental Technology Verification (ETV) Program to facilitate the deployment of innovative environmental technologies through performance verification and dissemination of information. The goal of the ETV Program is to further environmental protection by accelerating the acceptance and use of improved and cost-effective technologies. ETV seeks to achieve this goal by providing high-quality, peer-reviewed data on technology performance to those involved in the design, distribution, financing, permitting, purchase, and use of environmental technologies. ETV works in partnership with recognized testing organizations; with stakeholder groups consisting of buyers, vendor organizations, and permitters; and with the full participation of individual technology developers. The program evaluates the performance of innovative technologies by developing test plans that are responsive to the needs of stakeholders, conducting field or laboratory tests (as appropriate), collecting and analyzing data, and preparing peer-reviewed reports. All evaluations are conducted in accordance with rigorous quality assurance (QA) protocols to ensure that data of known and adequate quality are generated and that the results are defensible. The EPAs National Exposure Research Laboratory (EPA NERL) and its verification organization partner, Battelle, operate the Advanced Monitoring Systems (AMS) Center under ETV. The AMS Center recently evaluated the performance of the Sensicore WaterPOINT 870 (WP870), a multi-parameter water sensor. This test was carried out in collaboration with the Columbus, Ohio Department of Public Utilities Division of Power and Water (CDW). |
Supplementary Notes |
Microfiche reproduction is in black and white. Sponsored by the Environmental Protection Agency, Research Triangle Park, N.C. |
Availability Notes |
Also available on CD-ROM. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
NTIS Title Notes |
ETV rept. |
Category Codes |
68; 68D; 70E; 70F; 91A; 43F; 46B; 96D |
NTIS Prices |
PC A04/MF A01 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
009400690 |
Origin |
NTIS |
Type |
CAT |