Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 425 OF 1680

Main Title Development and Applications of CFD in Support of Air Quality Studies of Roadway and Building Microenvironments.
Author Huber, A. H. ; Freeman, M. ; Rida, S. ; Kuehlert, K. ; Bish, E. ;
CORP Author Fluent, Inc., Lebanon, NH. ;Scientific Visualization Center, Research Triangle Park, NC.;Agency for Healthcare Research and Quality, Rockville, MD. Center for Research Dissemination and Liaison.
Publisher 2003
Year Published 2003
Report Number EPA/600/A-01/035;
Stock Number PB2004-104065
Additional Subjects Air pollution sources ; Air quality ; Roads ; Buildings ; Exposure ; Models ; Urban areas ; Turbulence ; Aerodynamics ; Regulations ; Pollution prevention ; Case studies ; Computational fluid dynamics(CFD)
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2004-104065 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 24p
Abstract There is a need to develop modeling and data analysis tools to increase our understanding of human exposures to air pollutants beyond what can be explained by 'limited' field data. Modeling simulations of complex distributions of pollutant concentrations within roadway and building microenvironments is feasible using high performance computing. Output from high performance computing can both be directly used to better understand specific exposure events and used to develop better simplified model approximations that may be generally applied. Unlike most currently and regulatory air quality models, Computational Fluid Dynamics (CFD) simulations are able to account rigorously for topographical details such as terrain variations and building structures in urban areas as well as local aerodynamics and turbulence. This paper discusses the development and application of CFD simulations through case studies using Fluent, Inc Computational Fluid Dynamics software for simulating air pollutant concentrations from sources near roadways and buildings. Comparisons of CFD simulations to both wind tunnel and field measured wind and pollutant concentrations are being used to provide evaluation/validation examples that document the reliability and accuracy of Fluent's existing CFD software.
Supplementary Notes Prepared in cooperation with Scientific Visualization Center, Research Triangle Park, NC. Sponsored by Agency for Healthcare Research and Quality, Rockville, MD. Center for Research Dissemination and Liaison.
Availability Notes Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Category Codes 68A; 46B; 91A
NTIS Prices PC A03/MF A01
Document Type NT
Cataloging Source NTIS/MT
Control Number 020000180
Origin NTIS
Type CAT