Main Title Operating a Small Full-Scale Ion Exchange System for Uranium Removal (Journal Version).
Author Jelinek, R. T. ; Sorg, T. J. ;
CORP Author Environmental Protection Agency, Cincinnati, OH. Drinking Water Research Div. ;Arber (Richard P.) Associates, Inc., Denver, CO.
Publisher c1988
Year Published 1988
Report Number EPA/600/J-88/140;
Stock Number PB89-119325
Additional Subjects Water pollution abatement ; Uranium ; Water wells ; Ion exchangers ; Design criteria ; Performance evaluation ; Cleanup operations ; Denver(Colorado)
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB89-119325 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 8p
Abstract The design and operation of a small full-scale ion exchange system used to remove uranium from well water in the foothills west of Denver, Colorado, are described. Consistent removal of uranium was accomplished by anion exchange treatment at a reasonable cost. Because of a lack of clear regulatory guidelines, disposal of the uranium-laden regenerant wastewater was the most complicated task associated with this treatment system. Gamma radiation buildup did not appear to be a health concern. (Copyright (c) Journal AWWA 1988.)
Supplementary Notes Prepared in cooperation with Arber (Richard P.) Associates, Inc., Denver, CO.
Availability Notes Pub. in Jnl. of the American Water Works Association, v80 p79-83 Jul 88.