Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 44 OF 87

Main Title Minimization of Interferences in Inductively Coupled Plasma Mass Spectrometry Using On-Line Preconcentration.
Author Heithmar, E. M. ; Hinners, T. A. ; Rowan, J. T. ; Riviello., J. M. ;
CORP Author Lockheed Engineering and Sciences Co., Inc., Las Vegas, NV. ;Dionex Corp., Sunnyvale, CA.;Environmental Monitoring Systems Lab., Las Vegas, NV.
Publisher c1990
Year Published 1990
Report Number EPA-68-03-3245; EPA/600/J-90/223;
Stock Number PB91-117150
Additional Subjects Concentrating ; Mass spectroscopy ; Titanium ; Manganese ; Iron ; Cobalt ; Nickel ; Copper ; Cadmium ; Lead(Metal) ; Reliability ; Matrix materials ; Waste water ; Standards ; Sea water ; Isotopes ; Trace elements ; Vanadium ; Reprints ; Interference
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB91-117150 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 10p
Abstract A semiautomated system is used to preconcentrate Ti, V, Mn, Fe, Co, Ni, Cu, Cd, and Pb, in order to remove high salt matrices. The preconcentration system accepts digests with acid concentrations equivalent to 0.8-1.4% HNO3, neutralizes them, and loads them onto a macroporous iminodiacetate resin. The alkali and alkaline-earth metals, along with deleterious anions such as chloride, are washed off the resin before and analyte metals are eluted with nitric acid. A total of 13 isotopes of the analytes are measured. An examination of the apparent concentration efficiencies, as well as the behavior of two internal standard elements added to the eluate stream, indicates that the elution front matrix enhances the inductively coupled plasma mass spectrometry response of the analytes. Investigation of the nature of the blank signals suggests that the detection limits of several of the isotopes could benefit by much larger preconcentration factors, while those of vanadium, copper, cadmium, and lead are currently limited by reagent purity and laboratory contamination. The preconcentration system is evaluated on several simple synthetic matrices, as well as on synthetic seawater and three wastewaters. Digestion of samples containing natural organic chelators is required. (Copyright (c) by the American Chemical Society, 1990.)
Supplementary Notes Pub. in Analytical Chemistry, v62 n8 p857-864 1990. Prepared in cooperation with Dionex Corp., Sunnyvale, CA. Sponsored by Environmental Monitoring Systems Lab., Las Vegas, NV.
NTIS Title Notes Journal article.
Title Annotations Reprint: Minimization of Interferences in Inductively Coupled Plasma Mass Spectrometry Using On-Line Preconcentration.
Category Codes 99A; 68D
NTIS Prices PC A02/MF A01
Primary Description 600/07
Document Type NT
Cataloging Source NTIS/MT
Control Number 101123963
Origin NTIS
Type CAT