Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 87 OF 613

Main Title Characterization of Emissions from Carpet Samples Using a 10-Gallon Aquarium as the Source Chamber.
Author Guo, Z. ; Roache, N. ;
CORP Author Acurex Corp., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Publisher Aug 94
Year Published 1994
Report Number EPA-68-DO-0141; EPA/600/R-94/141;
Stock Number PB94-210002
Additional Subjects Carpets ; Test methods ; Indoor air pollution ; Aerosols ; Emissions ; Response ; Toxicity ; Chemical analysis ; Concentration(Composition) ; Biological accumulation ; Physical properties ; Microbiologs ; Experimental design ; High temperature ; Tests ; Graphs(Charts) ; Samples ; Toxicology ; USEPA ; Tables(Data) ; Exposure chamber ; Stationary sources
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P1011ZJ7.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB94-210002 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 129p
Abstract The report discusses part of a Phase I carpet bioresponse study sponsored by EPA. The study evaluated emissions from carpet samples that had previously been reported to show toxic effects on experimental mice. The report describes the major findings of only the chemical characterization work conducted at the Indoor Source Characterization Laboratory of EPA's Air and Energy Engineering Research Laboratory. All other results (animal testing, microbial testing, chemical analysis by sample extraction, and pesticide analysis) are reported separately. The experimental system used in this study, developed by Anderson Laboratories, was identical to that used by EPA's Health Effects Research Laboratory in carpet bioresponse testing. An emissions characterization team from the Contractor evaluated the experimental system and concluded that all test system developed by Anderson Laboratories was not suitable for carpet chemical emissions characterization because of poor reproducibility, non-uniform thermal conditions, and emissions from the source chamber itself.
Supplementary Notes See also PB91-242966. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
NTIS Title Notes Final rept. Oct 92-Jun 93.
Category Codes 68A; 57Y; 71I; 89H
NTIS Prices PC A07/MF A02
Primary Description 600/13
Document Type NT
Cataloging Source NTIS/MT
Control Number 430124064
Origin NTIS
Type CAT