Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 11 OF 12

Main Title Stability/Instability of Gas Mixtures Containing 1,3-Butadiene in Treated Aluminum Gas Cylinders.
Author Rhoderick, G. C. ;
CORP Author National Inst. of Standards and Technology (NML), Gaithersburg, MD. Gas and Particulate Science Div.
Publisher 1990
Year Published 1990
Stock Number PB95-162285
Additional Subjects Butadienes ; Stability ; Gas cylinders ; Binary mixtures ; Calibration standards ; Nitrogen ; Air pollution ; Chemical analysis ; Quantity ratio ; Concentration(Composition) ; Reprints ; Aluminum gas cylinders ; 1,3-Butadiene
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB95-162285 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 9p
Abstract The Gas Metrology Research Group of the National Institute of Standards and Technology (NIST), has been involved in research and development of gas standards of volatile toxic organic compounds for many years. Over thirty toxic organic compounds have been studied in gas mixtures contained in high pressure aluminum gas cylinders with specially treated interior surfaces. Almost all compounds studied to date have shown very good long term stability at the parts-per-billion (ppb, nanomole/mole) to parts-per-million (ppm, micromole/mole) range. One exception, 1,3-butadiene, is a compound that many scientists and policy makers are very interested in measuring in the environment. The author discusses data obtained over several years for gas mixtures of 1,3-butadiene in nitrogen, at concentrations of 2 ppm, 100 ppb, and 10 ppb. The data demonstrate that mixtures of 1,3-butadiene at the 2 ppm level have remained stable for over three years. However, gas mixtures of 1,3-butadiene at the 10 ppb level have shown decreases in concentration of more than 70% over a two-year period. Decreases in the concentration of 1,3-butadiene have been observed immediately after the preparation of the gas mixture in several cylinders. This indicates that gas mixtures of 1,3-butadiene are not stable at the ppb levels and therefore are not reliable as accurate calibration standards.
Availability Notes Pub. in Proceedings of 1990 EPA/A&WMA International Symposium on Measurement of Toxic and Related Air Pollutants, Raleigh, NC., May 1990, p709-717.
NTIS Title Notes Final rept.
Title Annotations Reprint: Stability/Instability of Gas Mixtures Containing 1,3-Butadiene in Treated Aluminum Gas Cylinders.
Category Codes 68A; 99A
NTIS Prices Not available NTIS
Primary Description NBS-120
Document Type NT
Cataloging Source NTIS/MT
Control Number 503420069
Origin NTIS
Type CAT