Main Title Environmental Technology Verification Report, Groundwater Sampling Technologies, Geolog, Inc., Micro-Flo(Trade Mark) Bladder Pump Model 57400.
CORP Author Sandia National Labs., Albuquerque, NM.;Environmental Protection Agency, Washington, DC. Office of Research and Development.
Publisher Aug 2000
Year Published 2000
Report Number EPA/600/R-00/075;
Stock Number PB2003-106821
Additional Subjects Groundwater ; Sampling ; Technologies ; Pumps ; Technology transfer ; Centrifugal pumps ; Monitoring ; Water quality ; Evaluation ; Performance ; Demonstration projects ; Tests ; Test facilities ; Quality control ; Assessment ; Analysis ; Methodology ; Documentation ; Reports ; Precision ; Comparison ; Tables(Data) ; Groundwater sampling devices ; Bladder pumps ; Test design ; Water sampling devices
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2003-106821 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 48p
Abstract In August 1999, a demonstration study was conducted to verify the performance of six groundwater sampling devices: Multiprobe 100 (multi-level sampler, Burge Environmental, Tempe, AZ), SamplEase (bladder pump, Clean Environment Equipment, Oakland, CA), Well Wizard dedicated sampling system (bladder pump, QED Environmental, Ann Arbor, MI), Kabis sampler (discrete-level grab sampler, Sibak Industries, Solano Beach, CA), GoreSorber Screening Survey (diffusional sampler, W. L. Gore and Associates, Elkton, MD), and the Micro- Flo sampler (bladder pump, Geolog, Inc., Medina, NY). This report contains an evaluation of the Micro-Flo bladder pump. A brief outline of this report is as follows: Section 2 contains a brief description of the Micro-Flo bladder pump and its capabilities. Section 3 outlines a short description of the test facilities and a summary of the verification test design. Section 4 includes a technical review of the data, with an emphasis on assessing overall sampler performance. Section 5 presents a summary of the Micro-Flo sampling device. Appendix A contains performance data for the reference pump and Appendix B provides an assessment of quality control data associated with the analytical method used in this study.
Supplementary Notes Sponsored by Environmental Protection Agency, Washington, DC. Office of Research and Development.
Availability Notes Also available on CD-ROM. Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Category Codes 68D; 91A; 43F