Main Title |
In-stack plume opacity from electrostatic precipitator/scrubber system at Harrington unit 1 / |
Author |
Sparks, L. E. ;
Sparks, Leslie E.
|
CORP Author |
Industrial Environmental Research Lab., Research Triangle Park, NC. Particulate Technology Branch. |
Publisher |
U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor], |
Year Published |
1979 |
Report Number |
EPA-600/7-79-118 |
Stock Number |
PB-299 215 |
OCLC Number |
08276353 |
Subjects |
Electrostatic separators ;
Scrubber (Chemical technology)
|
Additional Subjects |
Southwestern Public Service Company ;
Air pollution control equipment ;
Scrubbers ;
Electrostatic precipitators ;
Mathematical models ;
Opacity ;
Particles ;
Industrial wastes ;
Combustion products ;
Plumes ;
Standards ;
Pressure ;
Collectors ;
Venturi scrubbers ;
Numerical solution
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-7-79-118 |
|
Headquarters Library/Washington,DC |
10/27/2014 |
ELBD ARCHIVE |
EPA 600-7-79-118 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-7-79-118 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-299 215 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
vi, 24 pages : illustrations ; 28 cm. |
Abstract |
The report gives results of theoretical modeling of particulate emission and in-stack plume opacity for the electrostatic precipitator (ESP)/scrubber system at Southwestern Public Service Company's Harrington Unit 1. The theoretical results of an emission rate of 17.8 ng/J and opacity of 35% are in good agreement with data from compliance testing of the unit. The calculations indicate that 20% opacity can be achieved (1) by increasing specific collector area (SCA) of the ESP by 25% and leaving the scrubber pressure drop alone, (2) by increasing scrubber pressure drop by a factor of 4 and leaving the ESP alone, (3) by replacing the existing marble bed scrubber with a venturi scrubber, increasing the pressure drop by 20%, and leaving the ESP alone, or (4) by doubling the SCA of the ESP and removing the scrubber. Calculations showing the impact of high in-stack opacity on the downwind appearance of the plume are also included. |
Notes |
"Industrial Environmental Research Laboratory, Particulate Technology Branch." "May 1979." Includes bibliographical references. "Program element no. EHE624A." |
Place Published |
Research Triangle Park, NC Springfield, Va. |
Corporate Au Added Ent |
Industrial Environmental Research Laboratory (Research Triangle Park, N.C.). Particulate Technology Branch. |
Title Ser Add Ent |
Research reporting series. Interagency energy-environment research and development ; EPA-600/7-79-118. |
PUB Date Free Form |
1979 |
Series Title Untraced |
Interagency energy/environment R & D program report ; EPA-600/7-79-118 |
Category Codes |
13B; 68A |
NTIS Prices |
PC A03/MF A01 |
Primary Description |
600/13 |
BIB Level |
m |
Medium |
unmediated |
Content |
text |
Carrier |
volume |
Cataloging Source |
OCLC/T |
Control Number |
323766769 |
OCLC Time Stamp |
20141023065136 |
Language |
eng |
SUDOCS Number |
EP 1.23/8:600/7-79-118 |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
02087cam 2200433Ia 45020 |