Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 357 OF 869

Main Title In-stack plume opacity from electrostatic precipitator/scrubber system at Harrington unit 1 /
Author Sparks, L. E. ; Sparks, Leslie E.
CORP Author Industrial Environmental Research Lab., Research Triangle Park, NC. Particulate Technology Branch.
Publisher U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor],
Year Published 1979
Report Number EPA-600/7-79-118
Stock Number PB-299 215
OCLC Number 08276353
Subjects Electrostatic separators ; Scrubber (Chemical technology)
Additional Subjects Southwestern Public Service Company ; Air pollution control equipment ; Scrubbers ; Electrostatic precipitators ; Mathematical models ; Opacity ; Particles ; Industrial wastes ; Combustion products ; Plumes ; Standards ; Pressure ; Collectors ; Venturi scrubbers ; Numerical solution
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101QC9B.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-7-79-118 Headquarters Library/Washington,DC 10/27/2014
ELBD ARCHIVE EPA 600-7-79-118 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-7-79-118 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-299 215 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation vi, 24 pages : illustrations ; 28 cm.
Abstract The report gives results of theoretical modeling of particulate emission and in-stack plume opacity for the electrostatic precipitator (ESP)/scrubber system at Southwestern Public Service Company's Harrington Unit 1. The theoretical results of an emission rate of 17.8 ng/J and opacity of 35% are in good agreement with data from compliance testing of the unit. The calculations indicate that 20% opacity can be achieved (1) by increasing specific collector area (SCA) of the ESP by 25% and leaving the scrubber pressure drop alone, (2) by increasing scrubber pressure drop by a factor of 4 and leaving the ESP alone, (3) by replacing the existing marble bed scrubber with a venturi scrubber, increasing the pressure drop by 20%, and leaving the ESP alone, or (4) by doubling the SCA of the ESP and removing the scrubber. Calculations showing the impact of high in-stack opacity on the downwind appearance of the plume are also included.
Notes "Industrial Environmental Research Laboratory, Particulate Technology Branch." "May 1979." Includes bibliographical references. "Program element no. EHE624A."
Place Published Research Triangle Park, NC Springfield, Va.
Corporate Au Added Ent Industrial Environmental Research Laboratory (Research Triangle Park, N.C.). Particulate Technology Branch.
Title Ser Add Ent Research reporting series. Interagency energy-environment research and development ; EPA-600/7-79-118.
PUB Date Free Form 1979
Series Title Untraced Interagency energy/environment R & D program report ; EPA-600/7-79-118
Category Codes 13B; 68A
NTIS Prices PC A03/MF A01
Primary Description 600/13
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
Control Number 323766769
OCLC Time Stamp 20141023065136
Language eng
SUDOCS Number EP 1.23/8:600/7-79-118
Origin OCLC
Type MERGE
OCLC Rec Leader 02087cam 2200433Ia 45020