Main Title Ultra high rate filtration of activated sludge plant effluent /
Author Nebolsine, Ross. ; Pouschine, Jr, Ivan ; Fan., Chi-Yuan
Other Authors
Author Title of a Work
Pouschine, Ivan.
Fan, Chi-Yuan,
CORP Author Hydrotechnic Corp., New York.
Publisher U.S. Environmental Protection Agency, National Environmental Research Center,
Year Published 1973
Report Number EPA-R2-73-222; EPA-17030-HMM
Stock Number PB-221 492
OCLC Number 01028013
Subjects Sewage--Purification--Filtration ; Sanitary engineering
Additional Subjects Sewage treatment ; Sewage filtration ; Activated sludge process ; Sewage filtration ; Coagulation ; Suspended sediments ; Efficiency ; Performance evaluation ; Biochemical oxygen demand ; Cost estimates ; Filter materials ; Inorganic phosphates ; Flow rate ; Water pollution ; Cleveland(Ohio) ; Tertiary sewage treatment ; Water pollution control ; ORM
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101AOIB.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA R2-73-222 Headquarters Library/Washington,DC 11/15/2013
ELBD ARCHIVE EPA R2-73-222 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD RPS EPA R2-73-222 repository copy AWBERC Library/Cincinnati,OH 04/13/2015
NTIS  PB-221 492 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation viii, 114 pages : illustrations, figures, tables ; 28 cm
Abstract Pilot plant studies were conducted at the Southerly Wastewater Treatment Plant in Cleveland to evaluate the capabilities of the deep bed, dual media, ultra high rate filtration process for treating an activated sludge plant secondary effluent. The principal parameter for evaluating process efficiency was suspended solids. High removals were obtained with respect to suspended solids and to pollutants associated with suspended solids. The removal of these pollutants reduced biochemical oxygen demand, chemical oxygen demand and total phosphate values. Capital costs for a filtration process of this type are estimated to range from $1,200,000 for a 25 MGD plant to $5,400,000 for a 200 MGD plant. Total treatment costs, including capital and operating charges, are estimated to be 4.32-2.97 cents/1000 gallons for the 25 and 200 MGD plants, respectively. (Modified author abstract)
Notes "April 1973." "Project no. 17030 HMM." "Prepared for Office of Research and Monitoring, U.S. Environmental Protection Agency." Includes bibliographical references (pages 73-74).
Place Published Washington, DC
Availability Notes Paper copy available from GPO $2.10 as EP1.23/2:73-222.
Corporate Au Added Ent United States. Environmental Protection Agency. Office of Research and Monitoring.
Title Ser Add Ent Research reporting series. Environmental protection technology ; 73-222.
PUB Date Free Form 1973
Series Title Traced Environmental protection technology series, EPA-R2-73-222.
Series Title Untraced Environmental protection technology series ; EPA-R2-73-222
NTIS Prices PC-GPO/MF A01-NTIS
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
OCLC Time Stamp 20150409125035
Language eng