Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 196 OF 1885

Main Title CCW Impoundment Assessment Report. Bruce Mansfield Power Plant, Beaver County, Pennsylvania.
CORP Author Lockheed Martin Corp., Edison, NJ.; Rizzo (Paul C.) Associates, Inc., Columbia, SC.; Environmental Protection Agency, Washington, DC.
Year Published 2009
Report Number EPA-R1-094157/09
Stock Number PB2010-106907
Additional Subjects Coal wastes ; Surface impoundments ; Electric power production plants ; Landfills ; Fossil fuel combustion wastes ; Field inspections ; Certifications ; Recommendations ; Stability analysis ; Waste management ; Coal-fired power plants ; Coal combustion waste (CCW) ; Bruce Mansfield Power Plant ; Beaver County (Pennsylvania)
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2010-106907 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 79p
Abstract The Bruce Mansfield plant is a coal-fired power plant located on the south bank of the Ohio River in Shippingport, Beaver County, Pennsylvania-owned and operated by First Energy Generation Corporation (First Energy). A Site Vicinity map is shown on Figure 1-1, and an aerial photograph of the plant is shown on Figure 1-2. Under normal operating conditions, byproducts of coal combustion, including fly ash, bottom ash, boiler slag, flue gas emission control residuals, and other general wastewater products, are sluiced or trucked into several storage basins east of the plant. The impoundments include a North Low Dissolved Solids Pond (North LDS), a South Low Dissolved Solids Pond (South LDS), and a West High Dissolved Solids Pond (West HDS). An East High Dissolved Solids pond exists at the Site as well, but it was decommissioned in 2003. These ponds are shown on the aerial photograph provided on Figure 1-3. A plan view and typical sections for these impoundments are included on Figures 1-4 and 1-5, respectively. In addition, fly ash and other generation byproducts are pumped seven miles away to the Little Blue Run Dam and Reservoir for permanent disposal. The Little Blue Run impoundment is not addressed in this report.
Supplementary Notes Prepared in cooperation with Rizzo (Paul C.) Associates, Inc., Columbia, SC. Sponsored by Environmental Protection Agency, Washington, DC.
Availability Notes Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5301 Shawnee Road, Alexandria, VA, 22312, USA.
PUB Date Free Form 8 Dec 2009
Category Codes 68C; 97K; 50B; 91A; 43F
NTIS Prices PC A06
Document Type NT
Medium Final Report
Cataloging Source NTIS/MT
Control Number 109202670
Origin NTIS
Type CAT