Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 1 OF 1

Main Title Demonstration of a closed loop reuse system in a fiberglas textile plant /
Author Thomas, S. H. ; Walch, D. R.
Other Authors
Author Title of a Work
Walch, D. R.
CORP Author Owens-Corning Fiberglas Corp., Toledo, OH.;Industrial Environmental Research Lab., Research Triangle Park, NC.
Publisher U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor],
Year Published 1980
Report Number EPA-600/2-80-040; EPA-S-801173; PB80197064
Stock Number PB80-197064
OCLC Number 08287327
Subjects Glass fiber industry--South Carolina--Anderson ; Water reuse--South Carolina--Anderson
Additional Subjects Owens-Corning Fiberglass Corporation ; Owens-Corning Fiberglas Corporation ; Industrial waste treatment ; Water pollution control ; Textile industry ; Textile processes ; Design ; Performance evaluation ; Sand filtration ; Activated carbon treatment ; Circulation ; Disinfection ; Process charting ; Coagulation ; Reclamation ; Waste water reuse
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=91004PE5.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAM  EPA-600/2-80-040 Region 1 Library/Boston,MA 05/25/2016
ELBD ARCHIVE EPA 600-2-80-040 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD RPS EPA 600-2-80-040 repository copy AWBERC Library/Cincinnati,OH 04/27/2020
NTIS  PB80-197064 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation viii, 99 pages : illustrations ; 28 cm.
Abstract The report describes work done toward providing a totally recycled water system for Owens-Corning's textile fiber manufacturing plant at Anderson, SC. (The work was based on pre-1968 pilot plant work by Owens-Corning that resulted in development of totally recycled industrial wastewater systems for all of their insulation manufacturing plants). Water quality requirements for the Anderson plant were considerably more stringent than for insulation manufacturing. Test and engineering design work started in 1973. Design work was completed in March 1977 and actual field work was started. All sanitary wastes from the plant were segregated for separate treatment. Much modification to the existing treatment was required to improve the quality of primary and secondary effluent for tertiary treatment. In the final process, biologically treated effluent is sand-filtered, followed by activated carbon adsorption and disinfection with chlorine. Major items of equipment added were a commercial upflow pressure sand filter and three upflow activated carbon columns with backwash capabilities. The quality of treated effluent is completely satisfactory for all plant operating requirements. Total recycle of treated effluent was realized in mid-1978 and has continued since then. Complete closed-loop operation had not yet been achieved. Discharge to Betsy Creek has been greatly reduced.
Notes "Owens-Corning Fiberglas Corporation." "January 1980." Includes bibliographical references. "Grant no. S801173, program element no. 1BB610."
Place Published Research Triangle Park, NC Springfield, Va.
Supplementary Notes See also report dated Feb 77, PB-271 990.
Corporate Au Added Ent Industrial Environmental Research Laboratory (Research Triangle Park, N.C.); Owens-Corning Fiberglass Corporation.
Title Ser Add Ent Research reporting series. Environmental protection technology ; EPA-600/2-80-040.
PUB Date Free Form 1980
Series Title Traced Research reporting series Environmental protection technology ;
Series Title Untraced Research reporting series. 2, Environmental protection technology ; EPA-600/2-80-040
NTIS Prices PC A06/MF A01
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
OCLC Time Stamp 20200425103438
Language eng
SUDOCS Number EP 1.23/2:600/2-80-040
Origin OCLC
Type MERGE
OCLC Rec Leader 02691cam 2200529Ia 45010