Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 15 OF 214

Main Title Arsenic removal from drinking water by coagulation/filtration U.S. EPA demonstration project at Village of Pentwater, MI / {electronic resource} :
Author J. M. VALIGORE ; A. S. C. Chen ; W. E. CONDIT ; L. Wang ; Valigore, Julia M.
Other Authors
Author Title of a Work
Chen, Abraham S.C.
Condit, Wendy E.
Wang, Lili.
CORP Author Battelle, Columbus, OH.; National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div.
Publisher National Risk Management Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency,
Year Published 2008
Report Number EPA-68-C-00-185; EPA/600/R-08/011
Stock Number PB2008-108870
OCLC Number 216880754
Subjects Water--Purification--Arsenic removal ; Water--Purification--Coagulation ; Water--Purification--Membrane filtration ; Water--Purification--Michigan--Pentwater (Village)
Additional Subjects Drinking water ; Arsenic removal ; Demonstration project ; Village of Pentwater MI ; Treatment system ; Macrolite media ; Evaluation
Internet Access
Description Access URL
http://www.epa.gov/nrmrl/pubs0705.html
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P1008BPX.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600/R-08/011 Headquarters Library/Washington,DC 04/04/2008
NTIS  PB2008-108870 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Edition Final performance evaluation report
Collation {76} p. : ill. : digital, PDF file
Abstract This report documents the activities performed during and the results obtained from the arsenic removal treatment technology demonstration project at the Village of Pentwater, MI facility. The objectives of the project were to evaluate: (1) the effectiveness of Kineticofs FM-260-AS treatment system using MacroliteR media in removing arsenic to meet the maximum contaminant level (MCL) of 10 Eg/L, (2) the reliability of the treatment system for use at small water facilities, (3) the required system operation and maintenance (O and M) and operator skill levels, and (4) the capital and O and M cost of the technology. The project also characterized water in the distribution system and residuals generated by the treatment process. The types of data collected included system operation, water quality, process residuals, and capital and O and M cost. After review and approval of the engineering plan by the State, the FM-260-AS treatment system was installed and became operational on November 22, 2005. The system consisted of one 96-in x 96-in steel contact tank and two 60-in x 96-in steel pressure tanks configured in parallel. Each pressure tank was loaded with 40 ft(sup 3) of Macrolite (Trade Name) media to which filtration rates up to 9.3 gpm/ft(sup 2) were applied The system used an existing chlorination system to oxidize As(III) and Fe(II) and the contact tank to improve the formation of As(V)-laden iron particles prior to filtration. An iron addition system was installed midway through the study to improve arsenic removal. On average, the system operated at approximately 350 gal/min (gpm) for 5.1 hr/day, producing 39,185,000 gal of water through December 8, 2006. This average flowrate corresponded to a contact time of 6.8 min and a filtration rate of 8.9 gpm/ft(sup 2). Several problems were encountered during the demonstration study, including programmable logic controller (PLC) settings, backwash and service flowrates, media loss, influent pressure spikes, and chlorine addition. The actions taken to address these problems are detailed in the report.
Notes "June 2008." "EPA/600/R-08/011." Title from title screen (viewed on March 31, 2008). Includes bibliographical references (p. 45-46).
Place Published Cincinnati, OH :
Supplementary Notes See also Six Month Evaluation, PB2008-101563. Sponsored by National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div.
Availability Notes Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Access Notes Mode of access: Internet. System requirements: Adobe Acrobat Reader.
Corporate Au Added Ent National Risk Management Research Laboratory (U.S.). Water Supply and Water Resources Division.
PUB Date Free Form Jan 2008
Category Codes 68D; 57U; 99A; 43F; 91A
NTIS Prices PC A06
BIB Level m
Medium electronic resource
Cataloging Source OCLC/T
Control Number 019000490
OCLC Time Stamp 20080331144746
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01973nam 2200445Ia 45020