Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 164 OF 876

Main Title Countercurrent rinsing on high-speed halogen tinplating line /
Author Pengidore, D. A.,
CORP Author National Steel Corp., Weirton, W. Va. Weirton Steel Div.;Industrial Environmental Research Lab., Research Triangle Park, N.C.
Publisher Environmental Protection Agency, Office of Research and Development, Office of Energy, Minerals, and Industry, Industrial Environmental Research Laboratory ; For sale by the National Technical Information Service,
Year Published 1977
Report Number EPA-600/2-77-191; EPA-S-801989; EPA-ROAP-21ADT-003
Stock Number PB-272 590
OCLC Number 03993109
ISBN pbk.
Subjects Halogens ; Plating baths
Additional Subjects Tin coatings ; Plating ; Industrial wastes ; Water pollution control ; Technology ; Performance evaluation ; Process charting ; Design criteria ; Equipment ; Materials recovery ; Halogen inorganic compounds ; Recirculation ; Rinsing ; Countercurrent rinsing process
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101KSA8.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
ELBD ARCHIVE EPA 600-2-77-191 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD RPS EPA 600-2-77-191 repository copy AWBERC Library/Cincinnati,OH 08/03/2020
ESAD  EPA 600-2-77-191 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-272 590 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation vii, 84 pages : illustrations ; 28 cm.
Abstract The report describes the results of the first use of countercurrent rinsing (involving the use of a compartmentized rinse tank) in high-speed strip plating lines. The objective of using this rinse method is to reuce the amount of water required so as to have a volume of liquid more easily handled in recovering chemicals. The first unknown studied was the operating performance of the multistage rinse system to determine if the basic principles of countercurrent rinsing would hold for a high-speed strip plating operation. Second was the best way to recover the chemicals in the concentrated stream from this rinse system. The report also describes problems encountered in recycling the concentrated rinse into the main plating system. It also describes new technology for solving these problems and an alternate method involving indirect recycling using the detinning plant.
Notes Prepared under Grant no. S801989, ROAP no. 21ADT-003, program element no. 1BB610. Issued Sept. 1977. Includes bibliographical references (page 53).
Place Published Research Triangle Park, N.C. Springfield, Va.
Corporate Au Added Ent Industrial Environmental Research Laboratory (Research Triangle Park, N.C.)
Corp Au Ser Add Ent United States. Environmental Protection Agency. Environmental protection technology series ; EPA-600/2-77-191.
NTIS Title Notes Final rept. Feb 73-May 76.
PUB Date Free Form 1977
Series Title Untraced Environmental protection technology series ; EPA-600/2-77-191
Category Codes 13B; 7A; 68D; 99B
NTIS Prices PC A05/MF A01
Primary Description 600/13