Main Title |
Superfund record of decision : Circuitron, NY : first remedial action. |
CORP Author |
United States. Environmental Protection Agency. |
Publisher |
U.S. Environmental Protection Agency, Office of Emergency and Remedial Response ; Reproduced by National Technical Information Service, |
Year Published |
1991 |
Report Number |
EPA/ROD/R02-91/138; EPA/ROD/R00-90/000 |
Stock Number |
PB92-963830 |
OCLC Number |
28537784 |
Subjects |
Hazardous waste sites--New York (State)--New York
|
Additional Subjects |
Hazardous materials ;
Volatile organic compounds ;
Pollution control ;
Electronics ;
Metal finishing ;
Soils ;
Sediments ;
Debris ;
Waste treatment ;
Activated carbon treatment ;
Adsorption ;
Storm sewers ;
Incinerators ;
Waste disposal ;
Decontamination ;
Vacuum apparatus ;
Superfund ;
First Remedial Action ;
East Farmingdale(New York) ;
Vapor extraction
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
ELBD RPS |
EPA ROD-R02-91-138 |
repository copy |
AWBERC Library/Cincinnati,OH |
10/17/2014 |
NTIS |
PB92-963830 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
84 p. : ill. ; 28 cm. |
Abstract |
The one-acre Circuitron site is a former electronic circuit board manufacturing facility in East Farmingdale, Suffolk County, New York. Surrounding land use is industrial. From 1961 to 1986, circuit board manufacturing operations including metal plating were conducted onsite. Several onsite areas were used for discharge of process-generated wastes including one authorized and two unauthorized leaching pools. Circuitron remediated only one unauthorized leaching pool under the building and installed monitoring wells. In 1989, EPA removed 20 waste drums and contaminated debris from inside the building and three above-ground tanks from the rear of the building, and emptied two underground storage tanks. The selected remedial action for the site includes treating highly VOC-contaminated soil in the southwest corner of the site using in-situ vapor extraction; treating emissions using carbon adsorption and disposing of any spent carbon residuals offsite; excavating contaminated soil, sediment, and debris from the leaching pools, cesspools, and storm drains inside and outside of the building; incinerating these materials offsite, with offsite disposal of any residuals; decontaminating the building by vacuuming. |
Notes |
"03/29/91." "PB92-963830." "EPA/ROD/R02-91/138." "Office of Emergency and Remedial Response." |
Place Published |
Washington, D.C. Springfield, VA |
Supplementary Notes |
Portions of this document are not fully legible. |
Availability Notes |
Available on Standing Order, deposit account required for all RODS is $700 for U.S., Canada, and Mexico; all others $1,400. Deposit required for each region, $200, U.S., Canada, and Mexico; for all others $400. Also available individually in paper copy or microfiche. |
Corporate Au Added Ent |
United States. Environmental Protection Agency. Office of Emergency and Remedial Response. |
PUB Date Free Form |
1991 |
NTIS Prices |
PC A05/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20130212144847 |
Language |
eng |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01283cam 2200313Ka 45020 |