Main Title Coal Combustion Waste Impoundment (Task 3) Dam Assessment Report: E.W. Brown Plant, Main Fly Ash Pond Dam, E.ON U.S. LLC, Harrodsburg, Kentucky. Draft.
CORP Author Dewberry and Davis, Fairfax, VA.; Lockheed Martin, Edison, NJ.; Environmental Protection Agency, Cincinnati, OH.
Year Published 2009
Report Number EP-C-04-032-REAC
Stock Number PB2010-110179
Additional Subjects Electric power production plants ; Dam safety ; Coal wastes ; Waste management ; Surface impoundments ; Structural stability ; Surveillance ; Monitoring ; Field assessments ; Construction ; Operations ; Coal ash ; Recommendations ; Landfills ; Kentucky ; EW Brown Plant ; Main Fly Ash Pond Dam ; Coal combustion surface impoundments ; Fossil fuel combustion wastes ; Earth embankment dam ; EON US LLC ; Harrodsburg(Kentucky) ; REAC Program
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2010-110179 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 37p
Abstract The release of over five million cubic yards of coal ash from the Tennessee Valley Authority's Kingston, Tennessee, facility in December 2008, which flooded more than 300 acres of land, damaging homes and property, is a wake-up call for diligence on coal combustion waste disposal units. The government and utilities must marshal best efforts to prevent such catastrophic failure and damage. A first step toward this goal is to assess the stability and functionality of the ash impoundments and other units, then quickly take any needed corrective measures. This assessment of the stability and functionality of the E. W. Brown Main Fly Ash Dam management unit is based on a review of available documents and on the site assessment conducted by Dewberry personnel on Tuesday, October 20, 2009. Dewberry found the supporting technical documentation adequate (Section 1.1.3). As detailed in Section 1.2.6, there are recommendations that may help to maintain a safe and trouble-free operation; Dewberry recommends an updated dam break analysis (currently in progress).
Supplementary Notes Sponsored by Lockheed Martin, Edison, NJ. and Environmental Protection Agency, Cincinnati, OH.
Availability Notes Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5301 Shawnee Road, Alexandria, VA, 22312, USA.
PUB Date Free Form Nov 2009
Category Codes 68C; 68A; 97R; 91A; 43F
NTIS Prices PC A04
Document Type NT
Cataloging Source NTIS/MT
Control Number 118303150
Origin NTIS
Type CAT