Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 6 OF 21

Main Title Field tests of industrial stoker coal-fired boilers for emissions control and efficiency improvement, site D /
Author Gabrielson, J. E. ; Langsjoen, P. L. ; Kosvic., T. C.
Other Authors
Author Title of a Work
Langsjoen, Peter L.
Kosvic, T. C.
CORP Author KVB, Inc., Minneapolis, MN.;Industrial Environmental Research Lab., Research Triangle Park, NC.;Department of Energy, Washington, DC. Div. of Power Systems.;American Boiler Manufacturers Association, Arlington, VA.
Publisher The Office ; Available to the public through the National Technical Information Service,
Year Published 1979
Report Number EPA-600/7-79-237a; DOE-EF-77-C-01-2609
Stock Number PB80-144991
OCLC Number 07793337
Subjects Coal-fired furnaces--Testing ; Coal-fired furnaces--Environmental aspects ; Flue gases--Measurement ; Fly ash--Measurement
Additional Subjects Air pollution control ; Boilers ; Stokers ; Combustion products ; Oxygen ; Carbon dioxide ; Carbon monoxide ; Nitrogen oxide(NO) ; Sulfur dioxide ; Sulfur trioxide ; Concentration(Composition) ; Field tests ; Efficiency ; Particle size distribution ; Performance evaluation ; Air pollution sampling ; Coal combustion
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9100BQ63.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-7-79-237a c.1 Headquarters Library/Washington,DC 05/19/2014
EKBD  EPA-600/7-79-237a Research Triangle Park Library/RTP, NC 01/09/2004
ELBD ARCHIVE EPA 600-7-79-237a Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-7-79-237a Region 10 Library/Seattle,WA 04/04/2017
NTIS  PB80-144991 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation vi, 109 pages : illustrations ; 28 cm.
Abstract The report gives results of field measurements made on a 90,000 lb/hr vibrating-grate-stoker boiler. The effect of various parameters on boiler emissions and efficiency was studied. Parameters included overfire air, excess air, boiler load, and fuel properties. Measurements included gaseous emissions, particulate emissions, particle size distribution of the flyash, and combustible content of the ash. Gaseous emissions measured were O2, CO2, CO, NO, SO2, and SO3 in the flue gas. Sample locations included the boiler outlet and the multiclone dust collecter outlet. In addition to test results and observations, the report describes the facility tested, coals fired, test equipment, and procedures.
Notes "Industrial Environmental Research Laboratory, Office of Environmental Engineering and Technology, Research Triangle Park, N.C." "KVB, Inc." "November 1979." "IAG/contract nos. IAG-D7-E681 (EPA), EF-77-C-01-2609 (DoE), program element no. EHE624."
Place Published Washington, D.C. Springfield, Va.
Supplementary Notes See also report dated Dec 78, PB-293 731. Sponsored in part by American Boilers Manufacturers Association, Arlington, VA.
Corporate Au Added Ent Industrial Environmental Research Laboratory (Research Triangle Park, N.C.); United States. Environmental Protection Agency. Office of Research and Development.; United States. Department of Energy. Division of Power Systems. Energy Technology Branch.; American Boiler Manufacturers' Association.; KVB, inc.
Title Ser Add Ent Research reporting series. Interagency energy-environment research and development ; EPA-600/7-79-237 a.
NTIS Title Notes Final rept. Jul-Sep 78.
PUB Date Free Form 1979
Series Title Untraced Interagency energy/environment R & D program report ; EPA-600/7-79-237a
Category Codes 13B; 68A
NTIS Prices PC A06/MF A01
Primary Description 600/13
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
Control Number 323775287
OCLC Time Stamp 20130628112012
Language eng
SUDOCS Number EP 1.23/8:600/7-79-237 a
Origin OCLC
Type MERGE