Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 178 OF 281

Main Title Pilot Field Studies of FGD Waste Disposal at Louisville Gas and Electric.
Author Van Ness, R. P. ; Plumley, A. L. ; Mohn, N. C. ; Ullrich, C. R. ; Hagerty, D. J. ;
CORP Author Louisville Gas and Electric Co., KY.;Industrial Environmental Research Lab., Research Triangle Park, NC.
Year Published 1981
Report Number EPA-68-02-2143; EPA-600/7-81-155 ; IERL-RTP-1252
Stock Number PB82-105479
Additional Subjects Solid waste disposal ; Sludge disposal ; Air pollution control ; Earth fills ; Water pollution ; Flue gases ; Leaching ; Combustion products ; Industrial wastes ; Fly ash ; Electric power plants ; Sampling ; Louisville Gas and Electric Company ; Flue gas desulfurization ; Land disposal ; Limestone scrubbing
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB82-105479 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 314p
Abstract The report gives results of pilot field studies of flue gas desulfurization (FGD) waste disposal at Louisville Gas and Electric Co. The studies showed that properly prepared landfill from FGD sludge/fly ash mixtures can prevent trace element contamination of underlying groundwater. Analyses of leachates from the landfill impoundments studied showed that trace elements on the RCRA list of contaminants were found in concentrations below those proposed to characterize hazardous or toxic wastes. Decreasing concentrations, with time, of trace contaminants were observed in both leachate and runoff samples from the stabilized sludge mixtures. Small, synthetically lined, above-ground impoundments had higher concentrations of trace contaminants than subsurface impoundments since no attenuation by local soil was provided and vegetation that might minimize runoff was not established on these sites. Most sites developed compressive strengths significantly greater than the minimum required for recreational or light structural landfill. Water samples from beneath larger subsurface impoundments indicated that the filtering action of soil aids in decreasing the concentration of contaminants reaching the ground water supply. Certain mixtures have undergone a fixation reaction, reducing the permeability and minimizing the release of moisture and/or contaminants to the surrounding soil.
Supplementary Notes Prepared in cooperation with Combustion Engineering, Inc., Windsor, CT. Kreisinger Development Lab., and Louisville Univ., KY. Dept. of Civil Engineering.
NTIS Title Notes Final rept. May 76-Aug 79.
PUB Date Free Form 1981
Category Codes 13B; 68C; 68A; 68D; 97R
NTIS Prices PC A14/MF A01
Primary Description 600/13
Document Type NT
Cataloging Source NTIS/MT
Control Number 323804941
Origin NTIS
Type CAT