Main Title Negative Corona in Wire-Plate Electrostatic Precipitators. Part 2. Calculation of Electrical Characteristics of Contaminated Discharge Electrodes.
Author McLean, K. J. ; Lawless, P. A. ; Sparks, L. E. ; Ramsey, G. H. ;
CORP Author Wollongong Univ. (Australia). Dept. of Electrical and Computer Engineering. ;Research Triangle Inst., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Year Published 1986
Report Number EPA-68-02-3907; EPA/600/J-86/154;
Stock Number PB87-118063
Additional Subjects Electric corona ; Electrostatic precipitators ; Electrical properties ; Dust ; Contamination ; Performance ; Electric discharges ; Reprints ; Stationary sources
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB87-118063 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 14p
Abstract The article discusses the investigation of the characteristics of a single negative corona discharge tuft and how it interacts with another tuft when forced to do so. (Used during the investigation was a new analytical method developed to calculate the main electrical characteristics for a wire-plate geometry in which the wire is contaminated with dust and excited with a negative voltage.) Results were used to develop a complete analytical solution. The analysis identified a significant region of corona at voltages well below the peak critical voltage, Vc, beginning at the tuft onset voltage, Vt = 0.6 Vc. The method was also used to calculate the maximum current density under each tuft discharge and to make a reasonable estimate of the current distribution pattern on the plate and the number of tuft discharges per unit length of wire. (Copyright (c) Journal of Electrostatics, 1986.)
Supplementary Notes See also PB87-118055. Pub. in Jnl. of Electrostatics 18, p219-231 1986. Prepared in cooperation with Research Triangle Inst., Research Triangle Park, NC. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.