Main Title |
Arsenic Removal from Drinking Water by Coagulation/Filtration U.S. EPA Demonstration Project at Village of Waynesville, IL. Final Performance Evaluation Report. |
Author |
A. S. C. Chen ;
A. M. Paolucci ;
B. J. Yates ;
L. Wang ;
V. Lal
|
CORP Author |
Battelle, Columbus, OH.; ALSA Tech, LLC, Powell, OH.; National Risk Management Research Lab., Cincinnati, OH. Office of Research and Development.; National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div. |
Year Published |
2011 |
Report Number |
EPA/600/R-11/071; EP-C-05-057 |
Stock Number |
PB2012-101605 |
Additional Subjects |
Drinking water ;
Arsenic ;
Water treatment ;
Coagulation ;
Filtration ;
Water purification ;
Potable water ;
Demonstration projects ;
Effectiveness ;
Data collection ;
Performance evaluation ;
Peerless coagulation/filtration (C/F) system ;
GreensandPlus filtration media ;
Village of Waynesville (Illinois)
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2012-101605 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
91p |
Abstract |
This report documents the activities performed and the results obtained from the arsenic removal drinking water treatment technology demonstration project at the Village of Waynesville, IL. The main objective of the project was to evaluate the effectiveness of the Peerless coagulation/filtration (C/F) system, using GreensandPlus (Trademark) filtration media with an anthracite cap, in removing arsenic to meet the new arsenic maximum contaminant level (MCL) of 10 microgram/L. Additionally, this project evaluated (1) the reliability of the treatment system, (2) the required system operation and maintenance (O&M) and operator skill levels, and (3) the capital and O&M cost of the technology. The project also characterized the water in the distribution system and process residuals produced by the treatment process. The types of data collected during the demonstration period included system operation, water quality (both across the treatment train and in the distribution system), process residuals, and capital and O&M cost. |
Supplementary Notes |
Prepared in cooperation with ALSA Tech, LLC, Powell, OH. Sponsored by National Risk Management Research Lab., Cincinnati, OH. Office of Research and Development. and National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div. |
Availability Notes |
Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5301 Shawnee Road, Alexandria, VA, 22312, USA. |
PUB Date Free Form |
Jul 2011 |
Category Codes |
68D; 99B; 50B; 91A; 43F |
NTIS Prices |
PC A06 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
102300940 |
Origin |
NTIS |
Type |
CAT |