Main Title |
Fractional penetration of paint overspray arrestors |
Author |
Darvin, Charles H.
|
CORP Author |
Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. ;Research Triangle Inst., Research Triangle Park, NC. |
Publisher |
Air Pollution Prevention and Control Division, National Risk Management Research Laboratory, U.S. Environmental Protection Agency, |
Year Published |
1997 |
Report Number |
PB97-147953 ; EPA-600/R-97-011 |
Stock Number |
PB97-147953 |
OCLC Number |
37723672 |
Additional Subjects |
Spray painting ;
Air pollution control equipment ;
Filters ;
Performance evaluation ;
Paints ;
Emissions ;
Droplets ;
Air cleaners ;
Efficiency ;
Particles ;
Diameters ;
Quantitative analysis ;
Fractional penetration ;
Overspray arrestors ;
Pollution prevention
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EKBD |
EPA-600/R-97-011 |
|
Research Triangle Park Library/RTP, NC |
10/10/1997 |
NTIS |
PB97-147953 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
x, 94 p. : ill. ; 28 cm. |
Abstract |
The report describes the development of fractional penetration curves for liquid droplet penetration of overspray arrestors for discrete droplet diameters from 0.3 to 10 micrometers. These data points were obtained for two conditions: (1) for a clean arrestor, and (2) for an arrestor coated with paint. The paint was applied to the arrestor by spraying high solids baking enamel from a spray gun directed at the paint overspray arrestor with the air flowing at a face velocity of 120 fpm (0.61 m/sec). This work demonstrated that, for the conditions of the tests, the behavior of the paint overspray arrestor is peculiar to the design of the arrestor. The program also defined the efficiency of the test method used to define the fractional penetration. |
Notes |
Prepared for U.S. Environmental Agency, Office of Research and Development. "Control Technology Center" -- Cover. "February 1997." Includes bibliographical references (p.50) |
Place Published |
Research Triangle Park, N.C. : |
Supplementary Notes |
Prepared in cooperation with Research Triangle Inst., Research Triangle Park, NC. |
Availability Notes |
This product may be ordered from NTIS by phone at (703)487-4650; by fax at (703)321-8547; and by email at 'orders@ntis.fedworld.gov'. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Corporate Au Added Ent |
United States. Environmental Protection Agency. Air Pollution Prevention and Control Division. ; United States. Environmental Protection Agency. Office of Research and Development. ; United States. Environmental Protection Agency. Control Technology Center. |
PUB Date Free Form |
{1997} |
NTIS Prices |
PC A07/MF A02 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
19971002160823 |
Language |
ENG |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01195nam 2200265Ka 45020 |