Main Title |
Evaluation of Lithium Fluoride for Microwave Dosimetry Applications. |
Author |
Conove, David L. ;
|
CORP Author |
Bureau of Radiological Health, Rockville, Md. Div. of Electronic Products. |
Year Published |
1971 |
Report Number |
BRH/DEP-71-6; |
Stock Number |
PB-198 406 |
Additional Subjects |
( Lithium fluorides ;
Luminescent dosimeters) ;
( Thermoluminescence ;
Lithium fluorides) ;
Chemical dosimeters ;
Microwaves ;
Microwave dosimeters
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB-198 406 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
29p |
Abstract |
The use of LiF thermoluminescent dosimetry (TLD) material as a dosimeter for microwave radiation was evaluated. Teflon discs impregnated with LiF were subjected to saturation exposures (approximately 100,000 R) of gamma radiation, and these irradiated dosimeters were exposed to microwave radiation at 2450 MHz. Analysis of the relative light output data for the treatment groups indicated that there were no significant differences between groups. Hence, it was concluded that LiF, as used in the study, will not serve as a useful dosimeter for microwave radiation in the 2450-MHz frequency band. (Author) |