Main Title |
Environmental Technology Verification Report: Clarion Sensing Systems, Inc., Sentinal (Trade Name) 500 Series Continuous Multi-Parameter Water Quality Monitor. |
Author |
James, R. ;
Dindal, A. ;
Willenberg, Z. ;
Riggs, K. ;
|
CORP Author |
Battelle, Columbus, OH.;National Risk Management Research Lab., Cincinnati, OH. |
Publisher |
Oct 2005 |
Year Published |
2005 |
Stock Number |
PB2006-111257 |
Additional Subjects |
Water quality ;
Monitoring ;
Drinking water ;
Chemical contaminants ;
Water analysis ;
Chlorine ;
Temperature ;
Conductivity ;
Oxidation ;
Laboratory tests ;
Quality assurance ;
Verification ;
Technology assessment ;
Performance evaluation ;
Environmental technology verification (ETV) program ;
Clarion Sensing Systems Inc
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2006-111257 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
52p |
Abstract |
The Advanced Monitoring Systems (AMS) Center, one of six technology areas under ETV, is operated by Battelle in cooperation with EPA's National Exposure Research Laboratory. The AMS Center evaluated the performance of the Clarion Sensing Systems, Inc., Sentinal (Trade Name) 500 Series in continuously measuring free chlorine, temperature, conductivity, pH, and oxidation-reduction potential (ORP) in drinking water. This verification statement provides a summary of the test results. The performance of the Sentinal (Trade Name) 500 was assessed in terms of its accuracy, response to injected contaminants, inter-unit reproducibility, ease of use, and data acquisition. The verification test was conducted between August 9 and October 28, 2004, and consisted of three stages, each designed to evaluate a particular performance characteristic of the Sentinal (Trade Name) 500. All three stages of the test were conducted using a recirculating pipe loop at the U.S. EPA's Test and Evaluation (T&E) Facility in Cincinnati, Ohio. |
Supplementary Notes |
See also PB2006-104806. Sponsored by National Risk Management Research Lab., Cincinnati, OH. |
Availability Notes |
Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |