Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 10 OF 18

Main Title Development of Sampling and Analytical Procedure for Determining Hexachlorobenzene and Hexachloro-1,3-butadiene in Air.
Author Mann, Jon B. ; Enos, Henry F. ; Gonzalez, Jorge ; Thompson., John F. ;
CORP Author National Environmental Research Center, Research Triangle Park, N.C. Pesticides and Toxic Substances Effects Lab.
Year Published 1974
Stock Number PB-275 505
Additional Subjects Gas analysis ; Gas detectors ; Adsorbents ; Air pollution ; Chemical industry ; Industrial wastes ; Combustion products ; Chemical analysis ; Performance evaluation ; Chlorine organic compounds ; Reprints ; Benzene/hexachloro ; Air pollution detection ; Electron capture gas chromatography ; Butadiene/hexachloro
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-275 505 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 2p
Abstract Chromosorb 101 efficiently trapped vapors of hexachlorobenzene (HCB) and hexachloro-1,3-butadiene (HCBD) from air at a sampling rate of 3 l./min. No loss of efficiency was noted with sampling times of up to 3 hr. Increasing the sampling rate to 10 l./min. for 1 hr decreased the efficiency by 20%. The method as described has a detection limit of 28 ng of hexachlorobenzene per cubic meter of air.
Supplementary Notes Pub. in Environmental Science and Technology, v8 p584, Jun 74.
Availability Notes Included in the report, Journal Articles on Pesticide Chemical Analysis. Group 2, PB-275 495.
Title Annotations Reprint: Development of Sampling and Analytical Procedure for Determining Hexachlorobenzene and Hexachloro-1,3-butadiene in Air,
PUB Date Free Form 15 Jan 74
Category Codes 14B; 99A; 68A
NTIS Prices (Order as PB-275 495, MF A01)
Primary Description 500/01
Document Type NT
Cataloging Source NTIS/MT
Control Number 323729596
Origin NTIS
Type CAT