Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 32 OF 70

Main Title Environmental assessment of a coal/water slurry fired industrial boiler /
Author Van Buren, D. ; Waterland, L. R.
Other Authors
Author Title of a Work
Waterland, L. R.
CORP Author Acurex Corp., Mountain View, CA. Energy and Environmental Div.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Publisher U.S. Environmental Protection Agency, Air and Energy Engineering Research Laboratory,
Year Published 1986
Report Number EPA/600-7-86-012a; EPA/600-7-86-012b; EPA-68-02-3188
Stock Number PB86-183795
OCLC Number 828733760
Subjects Boilers--Environmental aspects--United States
Additional Subjects Environmental impacts ; Pollution ; Water tube boilers ; Slurries ; Assessments ; Coal ; Water ; Combustion ; Data ; Pollution control ; Fuel slurries
Internet Access
Description Access URL
Vol. 1 https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101IKZ1.PDF
Vol. 2 https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101GHZE.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EKBD  EPA-600/7-86-012a v.1 Research Triangle Park Library/RTP, NC 05/03/2023
EKBD  EPA-600/7-86-012b v.2 Research Triangle Park Library/RTP, NC 05/03/2023
ELBD ARCHIVE EPA 600-7-86-012a Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
NTIS  PB86-183795 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 2 volumes : illustrations, charts, facsimiles ; 28 cm
Abstract The report gives results of comprehensive emission measurements and analyses for a 7.6 kg/s (60,000 lb/hr) watertube industrial boiler firing a coal/water slurry. Measurements included continuous monitoring of flue gas; quantitation of semivolatile organics and 73 trace elements; volatile organic sampling train (VOST) quantitation of volatile organic priority pollutants; EPA Method 5/8 for particulate and SOx; controlled condensation for SOx; Andersen impactors for particle size distribution; and grab samples for N sub 2 O. Emissions of NOx, SO sub 2, CO, and hydrocarbons averaged 510, 450, 285, and 1 ppm, corrected to 3% oxygen. Particulate emissions were 4.3 g/dscm, and particle size was biased to larger size fractions with over half of particulate mass at 10 micrometers or greater. Combustible losses were high with over 40% carbon content in particulate. Total organic emissions were 15 to 17 mg/dscm with half in the C1 to C6 range. Napthalene was the only semivolatile detected.
Notes "April 1986." Final. "EPA Project Officer: J.A. McSorley." "EPA/600-7-86-012b." "EPA/600-7-86-012a." "Prepared for Office of Air Quality Planning and Standards; prepared by Air and Energy Engineering Research Laboratory"--Cover Includes bibliographical references. Contract Number: 68-02-3188
Contents Notes v. I. Technical results -- V. II. Data supplement.
Place Published Research Triangle Park, N.C.
Supplementary Notes See also Volume 2, PB86-183803. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Access Notes Also available via the World Wide Web.
Corporate Au Added Ent Air and Energy Engineering Research Laboratory.; United States. Environmental Protection Agency. Office of Air Quality Planning and Standards.; United States. Environmental Protection Agency. Office of Research and Development.
NTIS Title Notes Final rept. Jul 83-Apr 85.
PUB Date Free Form 1986
Category Codes 13B; 13A; 68A; 97J
NTIS Prices PC A05/MF A01
Primary Description 600/13
BIB Level m
Cataloging Source OCLC/T
Control Number 617118812
OCLC Time Stamp 20131104094206
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01806cam 2200397Ka 45020