Main Title Emissions test at an asphalt concrete production plant : Asphalt Plant "A", Clayton, North Carolina : volume 1 of 2. Appendices A & B /
Author Maret, M. D. ; Meadows, F.
CORP Author Pacific Environmental Services, Inc., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards.
Publisher U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards,
Year Published 2000
Report Number EPA/454/R-00/021A; EPA-68-D-70069
Stock Number PB2001-106032
Subjects Asphalt plants--Environmental aspects--North Carolina--Clayton ; Asphalt industry--Environmental aspects--North Carolina--Clayton ; Air--Pollution--North Carolina--Clayton
Additional Subjects Industrial plants ; Hot mix asphalts ; Emissions ; Kilns ; Air pollution control ; Manuals ; Test procedures ; Test locations ; Processes ; Rotary dryers ; Clayton(North Carolina) ; Manual methods testing
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000EX4Z.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2001-106032 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 201 pages ; 28 cm
Abstract The United States Environmental Protection Agency (USEPA) is investigating the asphalt concrete production source category to identify and quantify emissions of hazardous air pollutants (HAPS) from rotary aggregate dryers used at these facilities. There are two types of rotary drum dryers in use at asphalt concrete production plants; parallel flow, wherein the direction of travel of the drying aggregate is the same as the direction of travel of the burner exhaust gases, and counter flow, wherein the aggregate and exhaust gas flows are opposite to each other. On May 7, 1997, a work assignment was issued by EPA's Office of Air Quality Planning and Standards, Emissions Measurement Center, (OAQPS, EMC) to Pacific Environmental Services, Inc. (PES), of Research Triangle Park, North Carolina. The work assignment specified that emissions testing for HAPS be conducted on one of each type of aggregate dryer. Two candidate facilities were therefore identified and selected as host facilities for the testing program. This document describes the test procedures, results, and quality assurance procedures that ivere employed during the testing of a counter flow rotary drum aggregate dryer, which was located at Asphalt Plant 'A' in Clayton, North Carolina. The facility was identified as a candidate by EPA due to its location close to EPA facilities in Research Triangle Park, North Carolina, and because it is typical of counter flow rotary dryers in the asphalt production source category. The results of the emissions testing program conducted at a facility employing a parallel flow rotary aggregate dryer are presented in a separate report. The scope of the work assignment was to plan and conduct an air emissions testing program to quantify' emission rates of HAPS from the rotary aggregate drier located at Asphalt Plant 'A'.
Notes "Volume 1 of 2." Microfiche.
Place Published Research Triangle Park, NC :
Supplementary Notes See also PB2001-106033. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards.
Availability Notes Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Corporate Au Added Ent United States. Environmental Protection Agency. Office of Air Quality Planning and Standards.
Alternate Title Hot mix asphalt plants kiln dryer stack manual methods testing
PUB Date Free Form {2000}
NTIS Prices PC A11/MF A03
BIB Level m
Cataloging Source OCLC/T
OCLC Time Stamp 20010927165716
Language eng
Origin NTIS
Type MERGE
OCLC Rec Leader 01310nam 2200265Ka 45020