Main Title Modeling and Design Study Using HFC-236ea as an Alternative Refrigerant in a Centrifugal Compressor.
Author Popovic, P. ; Shapiro, H. N. ;
CORP Author Iowa State Univ., Ames. Dept. of Mechanical Engineering.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div.
Publisher Apr 97
Year Published 1997
Report Number EPA-R-820755-01-4; EPA/600/R-97/038;
Stock Number PB97-156129
Additional Subjects Centrifugal compressors ; Mathematical models ; Design analysis ; Refrigerants ; Hydrofluorocarbons ; Environmental chemical substitutes ; Alternatives ; Chlorofluorocarbons ; Naval vessels ; Air conditioning equipment ; Impellers ; Diffusers ; Chemical properties ; Physical properties ; Thermodynamic properties ; Comparisons ; Performance evaluation ; Air pollution abatement ; HFC-236ea ; CFC-114
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB97-156129 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 162p
Abstract The Environmental Protection Agency (EPA) in cooperation with the Navy has been seeking a CFC-114 drop-in placement. One alternative HFC refrigerant which appears to satisfy all physical and chemical characteristics for the Navy fleet was found to be HFC-236ea refrigerant. The project represents a part of the investigation directed to evaluate this CFC-114 alternative refrigerant as a possible drop-in replacement in Navy chillers. The objective of the study was to conduct a thorough literature review regarding centrifugal compressors and the, on the basis of the information gathered, build an accurate but simple compressor model utilizing the available compressor experimental data. Further, the developed compressor model would be used to suggest eventual design adjustments to enhance compressor performance with the alternative HFC-236ea refrigerant.
Supplementary Notes Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div.
Availability Notes This product may be ordered from NTIS by phone at (703)487-4650; by fax at (703)321-8547; and by email at 'orders@ntis.fedworld.gov'. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
NTIS Title Notes Final rept. Jan 94-Sep 95.
Category Codes 71M; 74E; 68A
NTIS Prices PC A09/MF A02
Primary Description 600/13
Document Type NT
Cataloging Source NTIS/MT
Control Number 720601700
Origin NTIS
Type CAT