Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 650 OF 1141

Main Title Microbiological alterations in distributed water treated with granular activated carbon /
Other Authors
Author Title of a Work
Haas, Charles N.
Publisher U.S. Environmental Protection Agency, Office of Research and Development, Municipal Environmental Research Laboratory,
Year Published 1983
Report Number EPA/600-S2-83-062
OCLC Number 76951290
Subjects Carbon, Activated ; Water--Purification--Adsorption
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000TNX7.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-S2-83-062 In Binder Headquarters Library/Washington,DC 10/30/2018
ELBD ARCHIVE EPA 600-S2-83-062 In Binder Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD  EPA 600-S2-83-062 AWBERC Library/Cincinnati,OH 01/03/2022
Collation 3 pages ; 28 cm
Notes "Sept. 1983." "EPA/600-S2-83-062." Caption title. Head of title--Project summary.
Contents Notes "Granular activated carbon (GAC) treatment of drinking water was investigated to determine its effects on the microbiological characteristics of potable water distribution systems. Though GAC is increasingly used to remove organic chemicals and reduce trihalomethane precursors from drinking water, concern exists that the practice may lead to increased microbial concentrations in the finished water. Microbial parameters examined were total coliforms (TC), endotoxins, standard plate count (SPC), membrane standard plate count (m-SPC), and acid-fast organisms (AF). An 18-month field investigation was held at two full-scale water treatment plants, and a pilot-scale study was conducted on GAC columns receiving prechlorinated, coagulated, and filtered water. The 18-month field investigation showed that such treatment does increase SPC and m-SPC organisms but has no effect on any of the other microbial parameters investigated. Furthermore, conventional postchlorination following GAC treatment appeared to mitigate any impact on the distributed water quality. Within the water distribution system itself, pH, temperature, and turbidity appeared to be positively correlated with SPC and m-SPC densities, with only sporadic inverse correlations to chlorine concentration. The pilot plant GAC studies using coagulated, postfiltration water were conducted to determine the effect of empty bed contact time (EBCT), velocity, and prechlorination on the microbial dynamics in GAC columns. Increasing EBCT by providing greater bed depth tended to stimulate microbial growth, but a decrease in velocity tended to depress microbial growth. Increasing levels of prechlorination tended to yield greater microbial concentrations on the carbon itself and to effect a slight increase in effluent microbial densities."
Place Published Cincinnati, OH
Access Notes Also available via the World Wide Web.
Corporate Au Added Ent Municipal Environmental Research Laboratory.
Alternate Title EPA-600/2-83-062
PUB Date Free Form 1983
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
OCLC Time Stamp 20211228213019
Language eng
SUDOCS Number EP 1.89/2:600/S 2-83-062
Origin OCLC
Type CAT
OCLC Rec Leader 01504cam 2200397Ia 45010