Main Title |
Air Velocities inside Domestic Environments: An Important Parameter in the Study of Indoor Air Quality and Climate. |
Author |
Matthews, T. G. ;
Thompson, C. V. ;
Wilson, D. L. ;
Hawthorne, A. R. ;
Mage, D. T. ;
|
CORP Author |
Oak Ridge National Lab., TN.;Environmental Protection Agency, Research Triangle Park, NC.;Department of Energy, Washington, DC. |
Year Published |
1987 |
Report Number |
CONF-870853-3-FP; AC05-84OR21400; |
Stock Number |
DE88004331 |
Additional Subjects |
Flow Rate ;
Residential Buildings ;
Air Flow ;
Anemometers ;
Comparative Evaluations ;
Indoor Air Pollution ;
Testing ;
Ventilation ;
ERDA/320107 ;
ERDA/500200 ;
Air quality
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
DE88004331 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
20p |
Abstract |
Air velocities have been measured in the master bedroom, kitchen, and basement of six occupied homes plus the dining/living room area of one unoccupied house. All of the houses have central, forced-air heating and air conditioning (HVAC) systems. Median air velocities of 5.3 and 12.4 cm/s were measured in all six occupied houses and the unoccupied house, respectively. Median velocities of 4.2, 4.3, and 10.2 cm/s were found in the master bedroom, basement, and kitchen of the six occupied homes, respectively. The elevated air velocities in the kitchen are consistent with increased occupant activities and use of ceiling and/or exhaust fans. The lowest median velocity of 1.1 cm/s was found in the master bedroom (with the forced air circulation off) where occupant entry and activities were purposely limited. Switching on the forced-air HVAC systems increased the median velocities from 5.8 to 6.2, 3.2 to 5.7, 1.5 to 8.1, and 4.4 to 15.5 cm/s in three occupied houses one unoccupied house, respectively, where the experimental data allowed such comparison. Low air velocities may sometimes be inadequate for quantitative passive monitoring of pollutant vapors. Ten and 50% reductions in sampling rate are noted from the literature for passive monitors at air velocities of <0.7-25 cm/s and <0.7-2 cm/sec, respectively. 14 refs., 6 figs. (ERA citation 13:018425) |
Supplementary Notes |
INDOOR AIR '87: 4th international conference on indoor air quality and climate, Berlin, F.R. Germany, 17 Aug 1987. |
Availability Notes |
Portions of this document are illegible in microfiche products. |
PUB Date Free Form |
1987 |
Category Codes |
89B |
NTIS Prices |
PC A03/MF A01 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
816211166 |
Origin |
NTIS |
Type |
CAT |