Main Title Validation of the Volatile Organic Sampling Train (VOST) protocol. : Volume 1. Laboratory validation phase /
Author Logan, T. J. ; Fuerst, R. G. ; Midgett, M. R. ; Prohaska, J.
Other Authors
Author Title of a Work
Logan, Thomas.
CORP Author PEI Associates, Inc., Cincinnati, OH.;Environmental Monitoring Systems Lab., Research Triangle Park, NC. Quality Assurance Div.
Publisher U.S. Environmental Protection Agency, Environmental Monitoring Systems Laboratory,
Year Published 1986
Report Number EPA/600/4-86/014A; EPA-68-02-3767
Stock Number PB86-145547
Subjects Hazardous wastes--Incineration--Measurement
Additional Subjects Air pollution ; Hazardous materials ; Trace elements ; Incinerators ; Sampling ; Performance evaluation ; Quality assurance ; Solid waste disposal ; Industrial wastes ; Combustion products ; Chemical analysis ; Sites ; Experimental design ; Volatile organic sampling trains ; Air pollution sampling ; Air pollution detection ; Principal organic hazardous constituents
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB86-145547 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 293 pages : illustrations ; 28 cm
Abstract The measurement of volatile organic emissions from a hazardous waste incinerator is one of the more difficult source testing problems. Specific compounds called principal organic hazardous constituents (POHC) are to be identified and quantified at levels of 0.5 to 100 ppb in hot, wet incinerator exhaust gas, which may also contain high particulate and acid levels. The protocol, which describes the practices used by laboratories making these measurements, allows for several alternative designs and operating procedures. The paper describes an experimental program to evaluate under controlled conditions in the laboratory as many of the acceptable practices as possible. It describes the results of sampling at various concentration levels using two tube configurations, two moisture levels and other procedural variations. These results have led to conclusions about the specific VOST procedures to be followed during the field validation studies.
Notes Caption title. "January 1986." Includes bibliographical references. "EPA/600/4-86/014." Microfiche.
Place Published Research Triangle Park, NC :
Supplementary Notes See also PB86-145554. Sponsored by Environmental Monitoring Systems Lab., Research Triangle Park, NC. Quality Assurance Div.
Corporate Au Added Ent Environmental Monitoring Systems Laboratory (Research Triangle Park, N.C.)
PUB Date Free Form 1986.