Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 31 OF 35

Main Title Stainless-Steel Soil Solution Sampler for Monitoring Pesticides in the Vadose Zone.
Author Smith, C. N. ; Carsel, R. F. ;
CORP Author Environmental Research Lab., Athens, GA.
Year Published 1986
Report Number EPA/600/J-86/013;
Stock Number PB86-177847
Additional Subjects Soil water ; Pesticides ; Lysimeters ; Samplers ; Design ; Leaching ; Stainless steels ; Monitoring ; Performance evaluation ; Drainage ; Unsaturation ; Test methods ; Georgia ; Reprints ; Vadose zone
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB86-177847 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 5p
Abstract A design for an in situ soil solution sampler (suction lysimeter), consisting of a stainless steel tube with a 0.1 MPa(-1.0 bar), high flow, porous ceramic cup, is presented for use in monitoring pesticide or other dissolved chemical leaching in the vadose (unsaturated) zone. The sampler is of one piece construction with the porous ceramic cup attached by epoxy adhesive. The design permits collection of a total volume of up to 0.5 of soil solution per sample. Laboratory studies indicated that pesticide sorption on the sampler was insignificant and no analytical interference problems were observed. The samplers were designed to monitor leaching of pesticides and inorganic tracers in an on-going field study in southwest Georgia.
Supplementary Notes Pub. in Soil Science Society of America Jnl., v50 n1 p263-265 Jan-Feb 86.
NTIS Title Notes Journal article.
Title Annotations Reprint: Stainless-Steel Soil Solution Sampler for Monitoring Pesticides in the Vadose Zone.
PUB Date Free Form 1986
Category Codes 6F; 14B; 68D; 57P
NTIS Prices PC A02/MF A01
Primary Description 600/01
Document Type NT
Cataloging Source NTIS/MT
Control Number 614223875
Origin NTIS
Type CAT