Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 4 OF 4

Main Title Versatile gas filter correlation spectrometer /
Author Burch, D. E. ; Burch, Darrell Eugene ; Gates, F. J. ; Gryvnak, D. A. ; Pembrook., J. D.
Other Authors
Author Title of a Work
Gates, Francis J.
Gryvnak, David A.
Pembrook, John D.
CORP Author Aeronutronic Ford Corp., Newport Beach, Calif. Aeronutronic Div.;Environmental Sciences Research Lab., Research Triangle Park, N.C.
Publisher U.S. Environmental Protection Agency, Environmental Sciences Research Laboratory,
Year Published 1975
Report Number EPA 600-2-75-024; U-6201; EPA-68-02-1227; EPA-ROAP-26ACV
Stock Number PB-251 577
OCLC Number 51934356
Subjects Spectrometers ; Air--Pollution--Measurement
Additional Subjects Gas analysis ; Spectrum analyzers ; Vinyl chloride ; Filters ; Instruments ; Exhaust gases ; Concentration(Composition) ; Automobiles ; Formaldehyde ; Ammonia ; Field tests ; Sensitivity ; Design criteria ; Performance evaluation ; Monitors ; Water ; Infrared spectrometers ; Air pollution detection ; Automobile exhaust
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=94008GNX.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
ELBD ARCHIVE EPA 600-2-75-024 AWBERC Library/Cincinnati,OH 08/19/2022
NTIS  PB-251 577 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation viii, 68 pages : illustrations ; 28 cm
Abstract A versatile infrared analyzer employing gas-filter correlation techniques has been designed and constructed to measure concentrations of pollutant gases from a variety of sources. The spectral bandpass is determined by an adjustable grating assembly. By interchanging cell windows, radiant energy sources, gratings, interference filters, and detectors, nearly any desired spectral bandpass between 0.3 micrometers and 11 micrometers can be obtained. Spectral curves of transmittance can also be scanned. A multiple-pass sample cell provides sample paths between approximately 4 m and 40 m. Shorter sample cells can also be employed. An H2O monitor measures the concentration of H2O in the multiple-pass sample cell and automatically accounts for interference by H2O in the measurement of other gas concentrations. Tests have been performed on the measurement of formaldehyde, vinyl chloride and ammonia. The minimum detectable concentration of formaldehyde in automotive exhaust is approximately 0.05 ppm.
Notes "EPA-600/2-75-024." EPA contract no. 68-02-1227. EPA project officer: F.M. Black. Includes bibliographical references (page 57).
Place Published Research Triangle Park, N.C.
Corporate Au Added Ent Environmental Sciences Research Laboratory.; United States. Environmental Protection Agency. Office of Research and Development.; Aeronutronic Ford Corporation.
Title Ser Add Ent Research reporting series. Environmental protection technology ; EPA-600/2-75-024.
PUB Date Free Form August 1975
Series Title Untraced Environmental protection technology series ; EPA-600/2-75-024
NTIS Prices PC A04/MF A01
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
OCLC Time Stamp 20220809213022
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01829cam 2200445 a 45010