Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 19 OF 20

Main Title Test Methods to Characterize Particulate Matter Emissions and Deposition Rates in a Research House.
Author McBrian, J. ; Fortmann, R. ; Guo, Z. ; Mosley, R. B. ;
CORP Author ARCADIS Geraghty and Miller, Inc., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div.
Publisher 2000
Year Published 2000
Report Number EPA-68-C-99-201; EPA/600/A-00/061;
Stock Number PB2000-107843
Additional Subjects Particulates ; Emissions ; Air pollution monitoring ; Test methods ; Residential buildings ; Sampling ; Combustion ; Natural gas ; Kerosene ; Candles ; Stationary sources
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2000-107843 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 18p
Abstract The paper discusses test methods to characterize particulate matter (PM) emission and deposition rates in a research house. In a room in the research house, specially configured for PM source testing, a high-efficiency particle air (HEPA)-filtered air supply system, used for positive pressurization of the room, minimizes PM infiltration from the outdoors and the rest of the house while a portable HEPA filter in the room reduces background PM prior to the start of source tests. A ceiling fan and portable air conditioner provide mixing and temperature control. Testing involves simultaneous real-time particle monitoring and integrated sampling. Particulate matter with aerodynamic diameters < 2.5 and 10 micrometers (PM2.5 and PM10, respectively) are collected on Teflon filters using size-selective cyclones operated at 16.7 L/min. Particle size distributions are measured with an electrical low-pressure impactor with 12 size fraction, from 0.030 to 10 micrometers in aerodynamic diameter.
Supplementary Notes Presented at Engineering Solutions to IAQ Problems, Raleigh, NC., July 17-19, 2000. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div.
Availability Notes Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
NTIS Title Notes Rept. for Oct 99-May 00.
Category Codes 68A; 97R
NTIS Prices PC A03/MF A01
Primary Description 600/13
Document Type NT
Cataloging Source NTIS/MT
Control Number 029900910
Origin NTIS
Type CAT