Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 48 OF 112

Main Title Fine Particle Emissions from Residual Fuel Oil Combustion: Characterization and Mechanisms of Formation.
Author Linak, W. P. ; Miller, C. A. ; Wendt, J. O. L. ;
CORP Author Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. ;Arizona Univ., Tucson. Dept. of Chemical and Environmental Engineering.
Publisher 2000
Year Published 2000
Report Number EPA/600/A-00/069;
Stock Number PB2001-100343
Additional Subjects Air pollution sampling ; Particulates ; Residual oils ; Measurement ; Combustion ; Air pollution control ; Stationary sources ; Emissions ; Combustion equipment
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P100SGPY.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2001-100343 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 24p
Abstract The paper gives results of a comparison of the characterisitics of particulate matter (PM) emitted from residual fuel oil combustion in two types of combustion equipment. A small commercial 732-kW fire-tube boiler yielded a weakly biomodal particulate size distribution (PSD) with > 99% of the mass contained in a broad coarse mode, and only a small fraction of the mass in an accumulation mode consistent with ash vaporization. Bulk samples collected and classified by a cyclone indicate that 30-40% of the total PM emissions were < about 2.5 micrometers aerodynamic diameter (PM2.5). The coarse mode PM was rich in char, indicating relatively poor carbon burnout, although calculated combustion efficiencies were > 99%. This characteristic behavior is typical of this type of small boiler. Larger scale, utility units firing residual oil were simulated using an 82-kW laboratory-scale refractory-lined combustor. PM emissions from this unit were in good agreement with published data, including published emission factors. These data indicate that the refractory-lined combustor produced lower total but greater fine particulate emissions, as evident from a single unimodal PSD centered at about 0.1 micrometer diameter. Bulk cyclone-segregated samples indicated that all the PM were smaller than 2.5 micrometers aerodynamic diameter.
Supplementary Notes Presented at the International Symposium on Combustion (28th), Edinburgh, Scotland, July 30-August 4, 2000. Prepared in cooperation with Arizona Univ., Tucson. Dept. of Chemical and Environmental Engineering.
Availability Notes Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
NTIS Title Notes Rept. for Jan 98-Jun 99.
Category Codes 68G; 97R
NTIS Prices PC A03/MF A01
Primary Description 600/13
Document Type NT
Cataloging Source NTIS/MT
Control Number 001700390
Origin NTIS
Type CAT