Full Record Display for the EPA National Library Catalog
RECORD NUMBER: 30 OF 30Main Title | Utility FGD (Flue Gas Desulfurization) Survey: October 1983-September 1984. Volume 2. Design Performance Data for Operating FGD Systems (Part 2). | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Author | Melia, M. T. ; McKibben, R. S. ; Pelsor, B. W. ; | |||||||||||
CORP Author | PEDCo-Environmental, Inc., Cincinnati, OH.;Environmental Protection Agency, Washington, DC. Stationary Source Compliance Div. | |||||||||||
Year Published | 1984 | |||||||||||
Report Number | EPA-68-02-3963; EPA/340/1-85/014C; | |||||||||||
Stock Number | PB86-147626 | |||||||||||
Additional Subjects | Electric power plants ; Air pollution control equipment ; Surveys ; Design criteria ; Performance evaluation ; Scrubbers ; Boilers ; Industrial wastes ; Combustion products ; Waste disposal ; Flue gases ; Flue gas desulfurization systems | |||||||||||
Holdings |
|
|||||||||||
Collation | 618p | |||||||||||
Abstract | The report, which is generated by a computerized data base system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) system. The three volume set summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. The development status (operational, under construction, or in the planning stages), system supplier, process, waste disposal practice, and regulatory class are tabulated alphabetically by utility company. Simplified process flow diagrams of FGD systems, definitions, and a glossary of terms are attached to the report. Current data for domestic FGD systems show 124 systems in operation, 25 systems under construction, and 68 systems planned. The current FGD-controlled capacity in the United States is 47,255 MW. | |||||||||||
Supplementary Notes | See also PB86-147618. Sponsored by Environmental Protection Agency, Washington, DC. Stationary Source Compliance Div. | |||||||||||
NTIS Title Notes | Final rept.. | |||||||||||
PUB Date Free Form | Oct 84 | |||||||||||
Category Codes | 13B; 68A; 97R | |||||||||||
NTIS Prices | PC A99/MF A01 | |||||||||||
Primary Description | 100/03 | |||||||||||
Document Type | NT | |||||||||||
Cataloging Source | NTIS/MT | |||||||||||
Control Number | 608719100 | |||||||||||
Origin | NTIS | |||||||||||
Type | CAT |