Main Title Lime/limestone flue gas desulfurization inspection and performance evaluation manual /
Author Kirshnan, E. R. ; McKibben, R. S. ; Melia, M. T. ; Laseke, B. A.
Other Authors
Author Title of a Work
Kirshnan, E. R.
CORP Author PEI Associates, Inc., Cincinnati, OH.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Publisher U.S. Environmental Protection Agency, Air and Energy Engineering Research Laboratory,
Year Published 1985
Report Number EPA 600-8-85-024; EPA-68-02-3995; PB86107398
Stock Number PB86-107398
OCLC Number 38145917
Subjects Flue gases--Desulfurization ; Lime ; Limestone ; Flue gases--Desulphurization
Additional Subjects Air pollution control equipment ; Manuals ; Performance evaluation ; Inspection ; Calcium carbonates ; Industrial wastes ; Combustion products ; Maintenance ; Limestone scrubbing ; Flue gas desulfurization
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000TJ0G.PDF
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=94002DGD.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
ELBD ARCHIVE EPA 600-B-85-024 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-8-85-024 Region 10 Library/Seattle,WA 01/02/1998
NTIS  PB86-107398 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 245 pages : illustrations ; 28 cm
Abstract The manual--on wet nonregenerable lime/limestone flue gas desulfurization (FGD) systems--is intended to guide Federal and State regulatory personnel concerned with the inspection and permitting of FGD systems for coal-fired steam electric generators in the U.S. It is a working document for someone who periodically inspects power plants to ensure their compliance with emission standards. Orientation material on the design, operating, and performance characteristics of FGD systems may also be helpful to the environmental regulatory agency permitter. With its goal of facilitating the systematic inspection of an FGD system to determine the system's present and probable future compliance status, the manual limits process theory to a necessary minimum and makes ample use of charts, checklists, and simplified diagrams in providing important guidelines and recommendations. Following the introductory section defining its purpose, approach, and scope, the manual contains sections on lime/limestone technology, performance monitoring, inspection methods and procedures, performance evaluation and problem diagnosis/correction, operation and maintenance, and safety. Appendices provide supplementary reference material, definitions of FGD terms, calculation sheets, and example checklists, the latter two for use by someone inspecting a plant.
Notes "September 1985." "EPA/600/8-85/024." "References: " R-1-R-2.
Place Published Research Triangle Park, NC
Supplementary Notes Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Corporate Au Added Ent Air and Energy Engineering Research Laboratory.
PUB Date Free Form 1985
NTIS Prices PC A14/MF A01
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
OCLC Time Stamp 20170831051313
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01443cam 2200385Ka 45010