Main Title An evaluation of full scale fabric filters on utility boilers : SPS Harrington Station Unit 3 /
Author Richardson, John W.,
Other Authors
Author Title of a Work
McKenna, J. D.,
Mycock, John C.,
Harmon, Dale Lynn,
Publisher Air and Energy Engineering Research Laboratory, Center for Environmental Research Information
Year Published 1985
Report Number EPA/600-S7-85-031a
OCLC Number 896828834
Subjects Fabric filters ; Coal-fired power plants ; Filters and filtration ; Contamination (Technology)
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000TNFV.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-S7-85-031a In Binder Headquarters Library/Washington,DC 10/17/2018
ELBD ARCHIVE EPA 600-S7-85-031a In Binder Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
Collation 3 pages : charts ; 28 cm
Notes "Sept. 1985." "EPA/600-S7-85-031a." At head of title: Project Summary. Caption title.
Contents Notes The objective of this program was to evaluate and characterize the performance of full-scale fabric filter unites installed on 100 MW or larger coal-fired power plants. This document reports results of total mass and fractional size particulate emission tests at Southwestern Public Service's Harrington Station Unit 3 from July 8 to July 11, 1981. Three outlet and one inlet mass and fractional size emission tests were performed. Due to the absence of inlet ports, inlet testing was done by bypassing the baghouse and testing at the outlet ports of the fabric filter. The fabric filter is a shake/deflate unit with 32 compartments. Each compartment has 204 bags, 30 ft 6 in. long and 11.5 in. in diameter. Design air/cloth ratio is 2.8. Average outlet concentration was 0.007 lb/106 Btu. Inlet loading was 2.0 /lb/106 Btu, giving a 99.65% collection efficiency. Particle sizing tests indicated that the mass geometric mean diameter for the three outlet tests ranged from 7.2 to 13 [mu]m with an inlet mass diameter of 60 [mu]m.
Place Published Research Triangle Park NC Cincinnati OH
Corporate Au Added Ent Air and Energy Engineering Research Laboratory.; ETS (Firm)
PUB Date Free Form 1985
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source RDA
OCLC Time Stamp 20141124160019
Language eng
Origin OCLC
Type CAT
OCLC Rec Leader 02574nam 2200421Ii 45020