Main Title |
N2O field study (final report) / |
Author |
Clayton, R. ;
Sykes, A. ;
Machilek, R. ;
Krebs, K. ;
Ryan, J.
|
Other Authors |
|
CORP Author |
Acurex Corp., Research Triangle Park, NC. Southeast Regional Office.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Air and Energy Engineering Research Laboratory, |
Year Published |
1989 |
Report Number |
EPA-68-02-4285; EPA/600/2-89/006 |
Stock Number |
PB89-166623 |
Subjects |
Nitric oxide--Measurement ;
Coal-fired power plants--Environmental aspects--United States
|
Additional Subjects |
Nitrogen oxide(N2O) ;
Gas analysis ;
Industrial wastes ;
Combustion products ;
Field tests ;
Sampling ;
Chemical analysis ;
Concentration(Composition) ;
Continuous sampling ;
Carbon monoxide ;
Carbon dioxide ;
Gas chromatography ;
Flame photometry ;
Sites ;
Nitrogen oxide(NO) ;
Oxygen ;
Air pollution sampling ;
Air pollution detection ;
Coal fired power plants ;
Electron-capture detectors ;
Stationary sources
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB89-166623 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
90 pages : illustrations ; 28 cm |
Abstract |
The report gives results of measurements of nitrous oxide(N2O) emissions from coal-fired utility boilers at three electric power generating stations. Continuous emissions monitor measurements were made for nitrogen oxide (NO), O2, CO2, and CO. On-line N2O measurements were made using a gas chromatograph (GC) with electron capture detection. On-line SO2 levels were measured on one unit using a GC with flame photometric detection. Stainless steel (SS) sample containers were used to collect flue gas samples for the evaluation of N2O formation as a function of time in the presence of NO, SO2, and water. The N2O on-line results were in the range from 'not detectable' to 4.6 ppm. The results did not exhibit apparent differences related to different boiler types and load conditions. |
Notes |
"Aug. 1989." "EPA/600/2-89/006." Microfiche. |
Place Published |
Research Triangle Park, NC : |
Supplementary Notes |
Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Corporate Au Added Ent |
Air and Energy Engineering Research Laboratory. |
PUB Date Free Form |
{1989} |
NTIS Prices |
PC A05/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20011119183453 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
00964nam 2200253Ka 45020 |