Main Title |
Pilot-scale tests and systems evaluation for the containment, treatment, and decontamination of selected materials from T&E building pipe loop equipment {electronic resource} / |
Other Authors |
|
CORP Author |
Shaw Environmental, Inc., Cincinnati, OH.; Environmental Protection Agency, Research Triangle Park, NC. National Homeland Security Research Center. |
Publisher |
Office of Research and Development, National Homeland Security Research Center, Water Infrastructure Protection, |
Year Published |
2008 |
Report Number |
EP-C-04-034; EPA/600/R-08/016 |
Stock Number |
PB2008-108877 |
Subjects |
Decontamination (from gases, chemicals, etc) ;
Water--Purification--Equipment and supplies ;
Water quality management ;
Buildings--Safety measures
|
Additional Subjects |
Water treatment ;
Water pollution control ;
Containment ;
Decontamination ;
Test and evaluation ;
Water distribution ;
Sodium arsenite ;
Mercuric chloride ;
Diesel fuels ;
Chlordance ;
Water management(Applied) ;
US EPA ;
Chemical removal(Water treatment)
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2008-108877 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Edition |
Final report. |
Collation |
{88} p. : digital, PDF file |
Abstract |
This report summarizes the pilot-scale evaluations conducted at the EPA Test and Evaluation (T&E) Facility between April 2005 and January 2007 to investigate removal of sodium arsenite, mercuric chloride, Bacillus subtilis, diesel fuel (No. 2), and chlordane from water distribution systems. The report covers the purpose of the study, detailed experimental test conditions and methods, analytical results, and observations. It also incorporates technical reviewer comments from American Water Works Association Research Foundation (AwwaRF) and Sandia National Laboratories on the draft summary reports that Shaw prepared for contaminant-specific evaluations conducted under this Work Assignment. |
Notes |
"EPA/600/R-08/016" "January 2008." "Contract no. GS-10F-0275K, Task Order 1105."????? Title from title screen (viewed on March 14, 2008). |
Contents Notes |
One of EPA's more important challenges in dealing with a contamination threat is how to treat, contain, and dispose of contaminated water. Depending on where the contaminant is introduced, this may involve actions within source waters, drinking water treatment plants, distribution systems, or points downstream. Any material (including the water) may need to be disposed of properly. Furthermore, the physical infrastructure of the water distribution system will require decontamination before it is reused. To evaluate the efficacy of various decontamination methods, a series of pilot-scale tests were conducted, using the pipe loop system located at the T&E Facility, in Cincinnati, Ohio. |
Place Published |
Cincinnati, OH : |
Supplementary Notes |
Sponsored by Environmental Protection Agency, Research Triangle Park, NC. National Homeland Security Research Center. |
Availability Notes |
Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Access Notes |
Mode of access: Internet. System requirements: Adobe Acrobat Reader. |
Corporate Au Added Ent |
Battelle Memorial Institute. Columbus Laboratories. ; United States. Environmental Protection Agency. Office of Research and Development. ; National Homeland Security Research Center (U.S.) Water Infrastructure Protection. |
Alternate Title |
Performance data for common building air cleaning devices |
PUB Date Free Form |
Jan 2008 |
Category Codes |
68D; 50B; 48G |
NTIS Prices |
PC A06 |
BIB Level |
m |
Medium |
electronic resource |
Cataloging Source |
OCLC/T |
Control Number |
019000610 |
OCLC Time Stamp |
20080318111242 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
02678cam 2200457Ia 45020 |