Main Title Process measurement procedures, H2SO4 emissions /
Author Maddalone, R. F. ; Garner, N.
Other Authors
Author Title of a Work
Garner, N.
CORP Author TRW Defense and Space Systems Group, Redondo Beach, CA.;Industrial Environmental Research Lab., Research Triangle Park, NC.
Publisher U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; Available to the public through the National Technical Information Service,
Year Published 1979
Report Number EPA-600/7-79-156; EPA-68-02-2165
Stock Number PB80-115959
OCLC Number 07855656
Subjects Sulfur trioxide ; Condensation ; Sulphur trioxide
Additional Subjects Sulfuric acid ; Aerosols ; Gas analysis ; Air pollution ; Particles ; Flue gases ; Industrial wastes ; Combustion products ; Separation ; Filtration ; Volumetric analysis ; Design ; Sampling ; Chemical analysis ; Laboratory equipment ; Performance evaluation ; Air pollution detection
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=500015VK.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-7-79-156 c.1 Headquarters Library/Washington,DC 02/04/2014
ELBD ARCHIVE EPA 600-7-79-156 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-7-79-156 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB80-115959 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation iv, 41 p. : ill. ; 28 cm.
Abstract The report gives procedures to measure H2SO4 vapor or aerosols in controlled or uncontrolled flue gas streams. The method was designed to operate at temperatures up to 250C with 3000 ppm SO2, 8-16% H2SO4, and up to 9 g/cu m of particulate matter. The basis of the method is the clean separation of particulate matter, H2SO4 vapor, and SO2. A heated (>250 C) quartz filter system removes the particulate matter, but passes most of the H2SO4 vapor to a modified Graham condenser. There the gas is cooled to about 62 C to condense and collect the H2SO4 vapor while passing the SO2 and H2O vapor. The condensed acid is titrated with either NaOH using bromophenol blue indicator or Ba(ClO4)2 using Sulfonazo III as the indicator. The laboratory coefficient of variance is + or - 6% and the estimated field accuracy is + or - 11%. Fly ash on the filter was shown to reduce the recovery of H2SO4 by 12% at the 10 ppm H2SO4 level. Field experiments showed that as little as 0.1 ppm H2SO4 could be detected.
Notes "TRW Defense and Space Systems Group." "Industrial Environmental Research Laboratory, Office of Energy, Minerals, and Industry." "July 1979." Includes bibliographical references. "Contract no. 68-02-2165, task no. 202, program element no. INE624."
Place Published Research Triangle Park, NC Springfield, Va.
Corporate Au Added Ent Industrial Environmental Research Laboratory (Research Triangle Park, N.C.); United States. Environmental Protection Agency. Office of Research and Development.; TRW Defense and Space Systems Group.
Title Ser Add Ent Research reporting series. Interagency energy-environment research and development ; EPA-600/7-79-156.
Alternate Title Process measurement procedures, H2SO4 emissions /
PUB Date Free Form 1979.
Series Title Untraced Interagency energy/environment R&D program report ; EPA-600/7-79-156
NTIS Prices PC A03/MF A01
BIB Level m
Cataloging Source OCLC/T
OCLC Time Stamp 20111219134101
Language eng
SUDOCS Number EP 1.23/8:600/7-79-156
Origin OCLC
Type MERGE
OCLC Rec Leader 01795cam 2200385Ia 45020